Neurologia medico-chirurgica
-
Neurol. Med. Chir. (Tokyo) · Apr 1999
Clinical TrialMesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute--technical note.
Expanded polytetrafluoroethylene (ePTFE) can be used as a dura substitute but is associated with leakage of cerebrospinal fluid (CSF) through the suture line. Fibrin glue alone may not prevent this problem. This new method for sealing the suture line in ePTFE membrane uses an absorbable polyglycoic acid mesh soaked with fibrinogen fluid placed on the suture line. ⋯ Our clinical experiences clearly show the efficacy of the mesh-and-glue technique to prevent CSF leakage after artificial dural substitution. Mesh and glue can provide an adequate repair for small dural defect. The mesh-and-glue technique may also be used for arachnoid sealing in spinal surgery.
-
Neurol. Med. Chir. (Tokyo) · Apr 1999
Case ReportsStereotactic radiosurgery for cavernous sinus cavernous hemangioma--case report.
A 40-year-old female presented with cavernous sinus cavernous hemangioma manifesting as left abducens and trigeminal nerve pareses. Magnetic resonance imaging revealed a left cavernous sinus tumor. The tumor was partially removed. ⋯ The tumor markedly decreased in size after radiosurgery and morbidity was avoided. Cavernous sinus cavernous hemangiomas may be difficult to treat surgically due to intraoperative bleeding and cranial nerve injury. Stereotactic radiosurgery can be used either as an adjunct treatment to craniotomy, or as the primary treatment for small cavernous sinus cavernous hemangioma.