Transfus Apher Sci
-
Transfusion of autologous whole blood is one available method to reduce the need for allogenic blood transfusion. The aim of the present study was to investigate the quality of shed blood collected in a new intraoperative autotransfusion system. ⋯ The basic laboratory characteristics of intraoperatively salvaged blood with the Sangvia® system are generally in the same range as reported in the studies on the postoperative transfusion of unwashed blood. From a blood quality point of view, our study indicates that transfusion of intraoperatively salvaged unwashed blood with the Sangvia® system in patients undergoing total hip arthroplasty is expected to be safe.