Oxygenation With a Single Portable Pulse-Dose Oxygen-Conserving Device and Combined Stationary and Portable Oxygen Delivery Devices in Subjects With COPD.
Portable oxygen devices simplify and facilitate patient therapy. This study was designed to compare S(pO2) and patient satisfaction with a portable oxygen concentrator or a combined system consisting of a fixed device with continuous-flow oxygen dispensation and a portable device with pulse dispensation for ambulation. ⋯ Subjects preferred using a single portable oxygenation system both at home and during ambulation. Portable systems alone, however, did not supply the same levels of oxygenation as the combination of fixed and portable systems. Before the widespread adoption of portable systems as a single device, additional studies are needed to determine best-practice protocols for adjustment of daytime and nighttime oxygenation settings. (ClinicalTrials.gov registration NCT02079753).
-
Sialorrhea or drooling represents quite a common problem in patients with amyotrophic lateral sclerosis (ALS). In this review, we describe the possible treatments for this issue. ⋯ In this review, we also explore the possible surgical options for treatment of sialorrhea. Although no specific studies have been conducted on patients with ALS, surgical therapies might represent a valid option for treatment of sialorrhea since there is no tachyphylaxis or need for repeated therapeutic sessions.
-
Inhaled corticosteroids (ICS) are the cornerstone of maintenance asthma therapy. However, in spite of this, adherence to ICS remains low. The aim of this systematic literature review was to provide an overview of the current knowledge of adherence to ICS, effects of poor adherence, and means to improve adherence. ⋯ Interventions to improve adherence show varying results, with most studies reporting an increase in adherence but unfortunately not necessarily an improvement in outcome. Even following successful interventions, adherence remains low. Further research is needed to explore barriers to adherence and interventions for improvement.
-
Multicenter Study
Single-Breath Diffusing Capacity for Carbon Monoxide Instrument Accuracy Across 3 Health Systems.
Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and repeatable D(LCO) values. ⋯ D(LCO) instrument accuracy was unacceptable in 43% of devices. Instrument inaccuracy can be primarily attributed to errors in inspired volume measurement and not gas analyzer performance. D(LCO) instrument performance may be improved by regular testing with a simulator. Caution should be used when comparing D(LCO) results reported from different laboratories.