Respiratory care
-
This study was designed to evaluate the influence of gender on the inhaler technique of subjects on inhaler therapy and to determine the factors predicting the correct inhaler technique and a change of inhaler device. ⋯ Errors in the inhaler technique, including inhalation maneuvers and device handling, were common in subjects on inhaler therapy. Subject-reported difficulties with using inhalers were more prevalent among female subjects, whereas errors in the inhaler technique identified by direct observation were similarly high in both genders. Overall, a lack of training on the inhaler technique predicted a higher likelihood of errors in the inhaler technique and a change of inhaler device.
-
High-flow nasal cannula (HFNC) is commonly used to provide respiratory support to pediatric patients with respiratory failure. Although the use of bronchodilators via HFNC has been described, the feasibility and safety of aerosolized bronchodilator delivery via HFNC are controversial. In this study, we sought to evaluate whether the HFNC system can be used to deliver nebulized bronchodilators at lower gas flow of 2-4 L/min, increase patient comfort, and minimize respiratory therapist (RT) bedside time when compared to traditional interfaces. ⋯ Aerosol bronchodilator delivery using HFNC is feasible at low gas flow (ie, 2-4 L/min). However, the use of HFNC did not improve subjects' comfort, and it increased RT bedside time. Further prospective randomized studies are needed to determine the efficacy and efficiency of aerosol therapy delivered through HFNC and potential patient-oriented outcomes.
-
Nebulizer therapy is an important treatment component for patients with cystic fibrosis (CF). Nebulizer manufacturers' guidelines advocate thorough nebulizer drying after washing. The aim of this study, therefore, was to examine the microbiology associated with nebulizer drying, particularly related to Pseudomonas control, and to examine microbiologically non-adherence to the recommended drying procedures. ⋯ This study demonstrated that nebulizer drying, if applied properly, had the ability to reduce counts of P. aeruginosa to non-detectable levels. Equally, this study showed that, if the device was not dried thoroughly and moisture remained, then the device was able to support the survival of P. aeruginosa at high numbers, which constituted an infection risk to the patient with CF. This information may help educate and inform the patient with CF about the importance of proper nebulizer drying for Pseudomonas control to improve patient awareness and safety.
-
Editorial Comment
Automated Oxygen Delivery and Conservation: Promises and Pitfalls.