Manual hyperinflation can be used to assist mucus clearance in intubated patients. The technique's effectiveness to move mucus is underpinned by its ability to generate flow bias in the direction of expiration, and this must exceed specific thresholds. It is unclear whether the inspiratory times commonly used by physiotherapists generate sufficient expiratory flow bias based on previously published thresholds and whether factors such as lung compliance affect this. ⋯ Inspiratory times of at least 3 s with normal compliance lungs and at least 2 s with lower compliance lungs appear necessary to achieve expiratory flow bias thresholds during manual hyperinflation. Inspiratory times shorter than this may lead to excessive peak inspiratory pressures. Verification of these findings in relation to the movement of mucus should be examined in further bench or animal models and/or human clinical trials.
-
Humidified, high-flow nasal cannula (HFNC) enables mucociliary clearance, accurate oxygen measurement, precise control of flow, and low-level positive airway pressure. There is sparse information concerning the timing of HFNC on patient outcomes such as incidence of adverse events during hospitalization, ICU stay, and post-ICU stay. ⋯ Study results provide preliminary evidence that early use of HFNC is beneficial in a medical and trauma ICU population, as it was associated with decreased ICU and post-ICU lengths of stay and reduced incidence of adverse events. This suggests that HFNC should be considered early in the ICU as first-line oxygen therapy.
-
Positive expiratory pressure (PEP) and CPAP are used to enhance breathing parameters such as functional residual capacity (FRC) in patients. Studies comparing effects of PEP and CPAP on FRC are few and variable. One reason for this may be that sophisticated equipment, not suitable in the clinical setting, is required. Because total lung capacity (TLC) consists of inspiratory capacity (IC) and FRC, a change in IC should result in a corresponding change in FRC given constant TLC. We aimed to evaluate the effects of different PEP and CPAP devices on IC as an indirect measure of induced changes in FRC from these devices in healthy subjects. ⋯ Provided that TLC is constant, we found that measurements of changes in IC could be used as an indirect measure of changes in FRC in healthy subjects. All investigated breathing devices except the PEP bottle decreased IC, as an indirect measure of increased FRC.
-
Compared with usual care, noninvasive ventilation (NIV) lowers the risk of intubation and death for subjects with respiratory failure secondary to COPD exacerbations, but whether administration of NIV by a specialized, dedicated team improves its efficiency remains uncertain. Our aim was to test whether a dedicated team of respiratory therapists applying all acute NIV treatments would reduce the risk of intubation or death for subjects with COPD admitted for respiratory failure. ⋯ The delivery of NIV by a dedicated team was associated with a lower risk of death or intubation in subjects with respiratory failure secondary to COPD exacerbations. Therefore, the implementation of a team administering all NIV treatments on a 24-h basis should be considered in institutions admitting subjects with COPD exacerbations.
-
Respiratory therapists (RTs) and other health-care workers are potentially exposed to a variety of aerosolized medications. The National Institute for Occupational Safety and Health (NIOSH) Health and Safety Practices Survey of Healthcare Workers describes current exposure control practices and barriers to using personal protective equipment during administration of selected aerosolized medications. ⋯ Despite the availability of safe handling guidelines for pentamidine, implementation was not universal, placing workers, co-workers, and even family members at risk of exposure. Although the antibiotics included in this study lack authoritative safe handling guidelines, prudence dictates that appropriate exposure controls be used to minimize exposure to the antibiotics and other aerosolized medications. Employers and employees share responsibility for ensuring that precautionary measures are taken to keep exposures to all aerosolized medications as low as practicable.