BMC anesthesiology
-
⋯ Our hypothesis that a program educating hospital staff to early detection and treatment of severe sepsis/septic shock may affect the outcome of all hospital patients is original, but it has to be corroborated by other experiences.
-
Interscalene block (ISB) is commonly performed using 20-40 mL of local anesthetic. Spread to adjacent structures and consequent adverse effects including paralysis of the ipsilateral hemidiaphragm are frequent. Pain ratings, analgesic requirements, adverse events, satisfaction, function and diaphragmatic excursion were compared following interscalene block (ISB) with reduced initial bolus volumes. ⋯ ISB provided reliable surgical analgesia with 5 mL, 10 mL or 20 mL ropivacaine (0.75%). The 20 mL volume was associated with increased complaints of dyspnea. The 5 mL volume was associated with statistically higher pain scores in the immediate postoperative period. Lower volumes resulted in a reduced incidence of dyspnea compared to 20 mL, however diaphragmatic impairment was not eliminated. Compensatory increases in contralateral diaphragmatic movement may explain tolerance for ipsilateral paresis.
-
⋯ Unsurprisingly, when used in a simulated difficult laryngoscopy, all the videolaryngoscopes resulted in a better view of the glottis than the Macintosh blade. However, interestingly the CMAC was found to provide a better laryngoscopic view that the Storz DCI Videolaryngoscope. Additionally, use of either the Glidescope or Storz DCI Videolaryngoscope resulted in a prolonged time to successful intubation compared with use of the CMAC or Macintosh blade. The use of the CMAC during manikin simulated difficult laryngoscopy combined the efficacy of attainment of laryngoscopic view with the expediency of successful intubation. Use of the Macintosh blade combined expedience with success, despite a limited laryngoscopic view. The limitations of a manikin model of difficult laryngoscopy limits the conclusions for extrapolation into clinical practice.
-
New laryngoscopes have become available for use in small children. The aim of the study was to compare the Storz® videolaryngoscope (SVL) to the Airtraq® Optical laryngoscope (AOL) for tracheal intubation in children younger than two years of age who had a normal airway assessment. Our hypothesis was that the SVL would have a better success rate than the AOL. ⋯ No difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq® Optical videolaryngoscope showed a number of time related advantages over the Storz® videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations.
-
⋯ Compared to more cranial levels, EA of the lower spine is associated with an increased risk of sanguineous and unsuccessful puncture. Insufficient analgesia more often accompanies high thoracic and low lumbar approaches. The risk of a sanguineous puncture increases in elderly patients. Gender, weight and body mass index seem to have no influence on the investigated complications.