BMC anesthesiology
-
Randomized Controlled Trial
Lung ultrasound is non-inferior to bronchoscopy for confirmation of double-lumen endotracheal tube positioning: a randomized controlled noninferiority study.
Appropriate placement of left-sided double-lumen endotracheal tubes (LDLTs) is paramount for optimal visualization of the operative field during thoracic surgeries that require single lung ventilation. Appropriate placement of LDLTs is therefore confirmed with fiberoptic bronchoscopy (FOB) rather than clinical assessment alone. Recent studies have demonstrated lung ultrasound (US) is superior to clinical assessment alone for confirming placement of LDLT, but no large trials have compared US to the gold standard of FOB. This noninferiority trial was devised to compare lung US with FOB for LDLT positioning and achievement of lung collapse for operative exposure. ⋯ In selected patients undergoing thoracic surgery requiring LDLT, lung ultrasonography was noninferior to fiberoptic bronchoscopy in achieving adequate lung collapse and reaches the desired outcome in less time.
-
Different types of anesthesia may affect cancer patient's outcomes, we compared the overall survival (OS) and disease-free survival (DFS) of patients with pancreatic cancer under total intravenous and inhalation anesthesia. ⋯ In conclusion, the present study showed no significant difference in overall survival and disease-free survival between total intravenous anesthesia and volatile anesthesia.
-
Cognitive ergonomics design of patient monitoring may reduce human factor errors in high-stress environments. Eye-tracking is a suitable tool to gain insight into the distribution of visual attention of healthcare professionals with patient monitors, which may facilitate their further development. ⋯ Critical anesthesia situations increased anesthesia personnel's visual interaction with the patient monitor. Furthermore, we found that their visual attention focused mainly on a few vital signs. To assist clinicians in critical situations, manufacturers should optimize monitors to convey necessary information as easily and quickly as possible and optimize the visibility of less frequently observed but equally critical vital signs, especially when they are in an abnormal range.
-
Randomized Controlled Trial
Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study.
The head-elevated laryngoscopy position has been described to be optimal for intubation, particularly in obese patients and those with anticipated difficult airways. Horizontal alignment of the external auditory meatus and sternal notch (AM-S) can be used as endpoints for optimal positioning. Thus, we aligned the head-elevated position with the AM-S in the horizontal plane and evaluated its effect on laryngeal visualization and ease of intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway. ⋯ In the head-elevated position, aligning the AM-S in the horizontal plane consistently improved laryngeal visualization without worsening the view when the McGrath MAC videolaryngoscope was used in patients with simulated difficult airways. It also improved the ease of intubation, which reduced the need for optimization maneuvers.
-
Intravenous regional anesthesia is an easy and reliable anesthetic technique, but its use is limited by tourniquet pain. Clonidine is effective in overcoming this shortcoming when used with intravenous regional anesthesia at a dose of 1 μg/kg. Dexmedetomidine has also been used successfully at a dose of 0.5 μg/kg. ⋯ We determined that the dexmedetomidine dose necessary to provide 50 min of pain free tourniquet time during intravenous regional anesthesia was higher than expected based on the relative alpha-2 adrenergic receptor selectivity of dexmedetomidine compared to clonidine.