Indian journal of anaesthesia
-
Direct laryngoscopy and tracheal intubation is a noxious stimulation that induces significant stress response. Currently, this nociceptive response is assessed mainly by haemodynamic changes. Recently, analgesia nociception index (ANI) is introduced into anaesthesia practice and provides objective information about parasympathetic (low nociceptive stress) and sympathetic (high nociceptive stress) balance, which reflects the degree of intraoperative nociception/analgesia. This study evaluated the changes in ANI and haemodynamics during anaesthetic induction and intubation, and their correlation during tracheal intubation. ⋯ Significant changes are observed in ANI during anaesthetic induction and intubation. There is a negative linear correlation between ANI and systemic haemodynamics during intubation.