Journal of anaesthesiology, clinical pharmacology
-
J Anaesthesiol Clin Pharmacol · Apr 2021
Comparison of the time taken for subarachnoid block using ultrasound-guided method versus landmark technique for cesarean section - A randomized controlled study.
Spinal anesthesia is the regional technique preferred for cesarean section and is usually administered using the traditional landmark technique. Ultrasonography of the spine appears to be helpful in locating the puncture site and increasing the success rate. The primary objective of this study was to assess the use of ultrasonogram in locating the lumbar interspinous space for spinal anesthesia in laboring parturients brought for elective cesarean section. ⋯ Preprocedural ultrasound is a useful tool for successful lumbar puncture in parturients as it minimizes the number of attempts of needle insertion and provides better patient satisfaction.
-
J Anaesthesiol Clin Pharmacol · Apr 2021
Laryngeal mask airway protector generates higher oropharyngeal leak pressures compared to the laryngeal mask airway supreme: A randomized clinical trial in the ambulatory surgery unit.
The Laryngeal Mask Airway (LMA) Protector™ is one of the latest introduced supraglottic airway devices. It provides access and functional separation of the respiratory and digestive tracts. Compared to the LMA Supreme™, it has two digestive ports, one to provide suction in the pharyngeal region and one for gastric tube insertion. High oropharyngeal leak pressure is a marker for safe ventilation when using LMA devices. We hypothesized that oropharyngeal leak pressure of the LMA Protector™ is 5 cm H2O higher than the oropharyngeal leak pressure of the LMA Supreme™ at various cuff volumes. Secondary outcome measures were ease of insertion of both masks, fiberoptic confirmation of correct positioning, failures of insertion, presence of blood staining, sore throat, presence of air leak and insertion time. ⋯ Oropharyngeal leak pressures were consistently higher (>5 cm H2O) for LMA Protector™ compared to LMA Supreme™. LMA Protector™, therefore, allows effective ventilation at higher airway pressures than LMA Supreme™.
-
J Anaesthesiol Clin Pharmacol · Apr 2021
A randomized control led study comparing CMAC video laryngoscope and Macintosh laryngoscope for insertion of double lumen tube in patients undergoing elective thoracotomy.
Double lumen tube (DLT) insertion for isolation of lung during thoracic surgery is challenging and is associated with considerable airway trauma. The advent of video laryngoscopy has revolutionized the management of difficult airway. Use of video laryngoscopy may reduce the time to intubate for DLTs even in patients with normal airway. ⋯ Macintosh blade is as good as CMAC (mac 3) blade to facilitate DLT intubation in adult patients with no anticipated airway difficulty, however CMAC was superior as it offers better laryngoscopic view, needed less force, and fewer external laryngeal manipulations.
-
J Anaesthesiol Clin Pharmacol · Apr 2021
ReviewSugammadex and anaphylaxis: An analysis of 33 published cases.
In this study, the published sugammadex-induced anaphylaxis reports were reviewed to determine similarities in their presentation during anesthesia. PubMed was searched for sugammadex-induced anaphylaxis without time limitation. Reports were evaluated if they were in English and met the criteria of anaphylaxis determined by the World Allergy Organization. ⋯ Sugammadex-induced anaphylaxis onset time was less than 5 min in 92.3% of all the reported cases. Rapid diagnosis and early recognition of signs and symptoms of anaphylaxis are essential for a favorable prognosis. Treatment needs to be started as soon as possible to ensure the best outcome for the patient.