Canadian Medical Association journal
-
Operating-room personnel exposed over a long period to trace concentrations of anesthetic gases may acquire both organic disturbances and impairment of cerebral function, though this has not been proven. However, the dangers of miscalculations due to disturbances of cerebral function and the fact that all working personnel should be breathing unpolluted air are sufficient indications to make scavenging of anesthetic gases mandatory. Scavenging has been carried out in many hospitals. At Vancouver General Hospital venting of the gases has decreased the nitrous oxide pollution to what is considered an acceptable level.
-
A case of lactic acidosis presented the opportunity for review of the association between lactic acidosis and ketoacidosis. The diagnosis of lactic acidosis or the combination of lactic acidosis and ketoacidosis is established clinically by the detection of a metabolic acidosis of the "unmeasured anion gap" type in the absence of significant renal failure, poison intake or a strongly positive clinical test for ketones. Before treatment can be planned the biochemical basis of lactic acidosis and ketoacidosis must be understood -- especially the fact that lactic acidosis is not a single disease entity but has many possible causes. ⋯ After recovery from metabolic acidosis of the unmeasured anion gap type, metabolic alkalosis is common. Decreased bicarbonate excretion plays an important role in the pathogenesis of the latter and may be the result of potassium or chloride loss, or both. The deficits, if present, should be corrected with appropriate therapy.
-
The Canadian Red Cross blood transfusion service has followed a set protocol for phlebotomy and collection of a unit of blood. Recent requirements for automated testing have necessitated that a second tube of blood be obtained from the blood line following collection of the unit. Evaluation of the techniques used, however, has indicated the possibility of bacterial contamination from the skin of donors, from insertion of the needle through an unsterile rubber stopper, and through backflow from a nonsterile vacuum tube. ⋯ The normal sampling procedure, which involves stripping the donor line to refill and mix the blood, was then followed. This resulted in contamination of the segments and even the blood bag. These findings led to modification of the standard bleeding technique, whereby stripping was eliminated and sterile vacuum tubes were to be used at all times.