Dissecting aortic aneurysms: accuracy of computed tomographic diagnosis.
During a three-year period, fifty patients were evaluated for the possibility of dissecting aortic aneurysm using high-resolution computed tomography (CT). The diagnosis of dissection was made if two contrast-medium-filled channels were identified within the aortic lumen. Eighteen patients were diagnosed with CT as having dissecting aortic aneurysms. ⋯ Follow-up was obtained in all patients. There were no known false-negative diagnoses and one false-positive diagnosis. High-resolution CT offers an accurate, noninvasive means to evaluate patients for suspected dissecting aortic aneurysms.