Radiology
-
Background There is growing evidence that digital breast tomosynthesis (DBT) results in lower recall rates and higher cancer detection rates when compared with digital mammography. However, whether DBT interpretative performance changes with experience (learning curve effect) is unknown. Purpose To evaluate screening DBT performance by cumulative DBT volume within 2 years after adoption relative to digital mammography (DM) performance 1 year before DBT adoption. ⋯ Recall rates decreased more in women with nondense breasts (OR range, 0.68-0.76; P < .001) than in those with dense breasts (OR range, 0.86-0.90; P ≤ .05; P interaction < .001). Cancer detection rates for DM and DBT were similar, regardless of DBT volume (P ≥ .10). Conclusion Early performance improvements after digital breast tomosynthesis (DBT) adoption were sustained regardless of DBT volume, radiologist subspecialty, or breast density. © RSNA, 2019 See also the editorial by Hooley in this issue.
-
Multicenter Study Comparative Study
Radiation Dose for Pediatric CT: Comparison of Pediatric versus Adult Imaging Facilities.
Background The American College of Radiology Dose Index Registry for CT enables evaluation of radiation dose as a function of patient characteristics and examination type. The hypothesis of this study was that academic pediatric CT facilities have optimized CT protocols that may result in a lower and less variable radiation dose in children. Materials and Methods A retrospective study of doses (mean patient age, 12 years; age range, 0-21 years) was performed by using data from the National Radiology Data Registry (year range, 2016-2017) (n = 239 622). ⋯ For example, abdomen-pelvis SSDE for the 14.5-18-cm size group was 3.6, 5.4, 5.5, and 8.3 mGy, respectively, for academic pediatric, nonacademic pediatric, academic adult, and nonacademic adult facilities (SSDE mean and variance P < .001). Mean SSDE for the smallest patients in nonacademic adult facilities was 51% (6.1 vs 11.9 mGy) of the facility's adult dose. Conclusion Academic pediatric facilities use lower CT radiation dose with less variation than do nonacademic pediatric or adult facilities for all brain examinations and for the majority of chest and abdomen-pelvis examinations. © RSNA, 2019 See also the editorial by Strouse in this issue.
-
Comparative Study
Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial.
Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. ⋯ Differences in sensitivity and specificity with the addition of CAD were small and not significant (P > .2). Conclusion Addition of digital breast tomosynthesis to digital mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. © RSNA, 2019 See also the editorial by Lång in this issue.