Radiology
-
High Incidence of Barotrauma in Patients with COVID-19 Infection on Invasive Mechanical Ventilation.
Background A high number of patients with coronavirus disease 2019 (COVID-19) pneumonia who had barotrauma related to invasive mechanical ventilation at the authors' institution were observed. Purpose To determine if the rate of barotrauma in patients with COVID-19 infection was greater than in other patients requiring invasive mechanical ventilation at the authors' institution. Materials and Methods In this retrospective study, clinical and imaging data of patients seen between March 1, 2020, and April 6, 2020, who tested positive for COVID-19 and experienced barotrauma associated with invasive mechanical ventilation, were compared with patients without COVID-19 infection during the same period. ⋯ Of 285 patients with acute respiratory distress syndrome on invasive mechanical ventilation during the previous 4 years (mean age, 68 years ± 17; 60% men), 28 patients (10%) had 31 barotrauma events, with an overall barotrauma rate of 11% (95% CI: 8%, 15%; P < .001 vs the group with COVID-19 infection). Barotrauma is an independent risk factor for death in COVID-19 (odds ratio = 2.2; P = .03) and is associated with a longer hospital stay (odds ratio = 0.92; P < .001). Conclusion Patients with coronavirus disease 2019 (COVID-19) infection and invasive mechanical ventilation had a higher rate of barotrauma than patients with acute respiratory distress syndrome and patients without COVID-19 infection. © RSNA, 2020 Online supplemental material is available for this article.
-
Background Water signal contamination is a major challenge for direct ultrashort echo time (UTE) imaging of myelin in vivo because water contributes most of the signals detected in white matter. Purpose To validate a new short repetition time (TR) adiabatic inversion recovery (STAIR) prepared UTE (STAIR-UTE) sequence designed to suppress water signals and to allow imaging of ultrashort T2 protons of myelin in white matter using a clinical 3-T scanner. Materials and Methods In this prospective study, an optimization framework was used to obtain the optimal inversion time for nulling water signals using STAIR-UTE imaging at different TRs. ⋯ A much lower mean UTE measure of myelin proton density was found in MS lesions (3.8 mol/L ± 1.5), and a slightly lower mean UTE measure was found in NAWM (7.2 mol/L ± 0.8) compared with that in NWM (8.0 mol/L ± 0.8) in the healthy volunteers (P < .001 for both comparisons). Conclusion The short repetition time adiabatic inversion recovery-prepared ultrashort echo time sequence provided efficient water signal suppression for volumetric imaging of myelin in the brain and showed excellent myelin signal contrast as well as marked ultrashort echo time signal reduction in multiple sclerosis lesions and a smaller reduction in normal-appearing white matter compared with normal white matter in volunteers. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Messina and Port in this issue.