Revista brasileira de anestesiologia
-
Rev Bras Anestesiol · May 2016
[Post analysis simulated correlation of the El-Ganzouri airway difficulty score with difficult airway].
Difficult airway (DA) occurs frequently (5-15%) in clinical practice. The El-Ganzouri Risk Index (EGRI) has a high sensitivity for predicting a difficult intubation (DI). However difficult mask ventilation (DMV) was never included in the EGRI. Since DMV was not included in the EGRI assessment, and obstructive sleep apnea (OSA) is also correlated with DMV, a study correlating the prediction of DA and OSA (identified by STOP-Bang questionnaire, SB) seemed important. ⋯ This study confirms that the incidence of DA is not negligible and suggests the use of the EGRI as simple bedside predictive score to improve patient safety.
-
Rev Bras Anestesiol · May 2016
[Good clinical practice guide for opioids in pain management: the three Ts - titration (trial), tweaking (tailoring), transition (tapering)].
Achieving good clinical practice in the use of opioids as part of a comprehensive pain management regimen can face significant challenges. Despite guidelines from governmental and pain society/organization sources, there are still significant hurdles. A review of some basic tenets of opioid analgesia based on current published knowledge and experiences about this important healthcare imperative is warranted. ⋯ We conclude that a simultaneously aggressive, yet conservative, approach is advocated in the literature in which opioid therapy is divided into three key steps (the 3 T's): titration (or trial), tweaking (or tailoring), and transition (or tapering). Establishment of the 3 T's along with the application of other appropriate good medical practice and clinical experience/judgment, including non-pharmacologic approaches, can assist healthcare providers in the effort to achieve optimal management of pain.
-
Rev Bras Anestesiol · May 2016
[Comparative study between benzydamine hydrochloride gel, lidocaine 5% gel and lidocaine 10% spray on endotracheal tube cuff as regards postoperative sore throat].
Postoperative sore throat is a common complication after endotracheal intubation. After tracheal intubation, the incidence of sore throat varies from 14.4% to 50%. The aim of the study was to compare between benzydamine hydrochloride gel, lidocaine 5% gel and lidocaine 10% spray on the endotracheal tube cuff as regards postoperative sore throat. ⋯ So in conclusion, benzydamine hydrochloride gel on the endotracheal tube cuff is a simple and effective method to reduce the incidence and severity of postoperative sore throat. Application of 10% lidocaine spray should be avoided because of worsening of postoperative sore throat where incidence increased but not the severity in relation to 5% lidocaine gel. Applying 5% lidocaine on the endotracheal tube cuff does not prevent postoperative sore throat but its application is better than lidocaine 10% spray or saline.
-
Rev Bras Anestesiol · May 2016
[Colonoscopy sedation: clinical trial comparing propofol and fentanyl with or without midazolam].
Colonoscopy is one of the most common procedures. Sedation and analgesia decrease anxiety and discomfort and minimize risks. Therefore, patients prefer to be sedated when undergoing examination, although the best combination of drugs has not been determined. ⋯ Patients in Group II had a higher incidence of reaction (motor or verbal) to the colonoscope introduction, bradycardia, hypotension, and increased propofol consumption. Patient satisfaction was higher in Group I. According to the methodology used, the combination of midazolam, fentanyl, and propofol for colonoscopy sedation reduces propofol consumption and provides greater patient satisfaction.
-
Rev Bras Anestesiol · May 2016
[A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin].
Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. ⋯ In a manikin, the Airtraq and the McGrath laryngoscopes appeared superior to the Macintosh laryngoscope when dealing with simulated airway scenarios. Both devices were associated with better views, intubation times and rates of success, especially in a simulated "difficult airway". Overall satisfaction was highest with the McGrath laryngoscope. Similar clinical studies are needed.