Revista brasileira de anestesiologia
-
Rev Bras Anestesiol · May 2016
[Comparative study between benzydamine hydrochloride gel, lidocaine 5% gel and lidocaine 10% spray on endotracheal tube cuff as regards postoperative sore throat].
Postoperative sore throat is a common complication after endotracheal intubation. After tracheal intubation, the incidence of sore throat varies from 14.4% to 50%. The aim of the study was to compare between benzydamine hydrochloride gel, lidocaine 5% gel and lidocaine 10% spray on the endotracheal tube cuff as regards postoperative sore throat. ⋯ So in conclusion, benzydamine hydrochloride gel on the endotracheal tube cuff is a simple and effective method to reduce the incidence and severity of postoperative sore throat. Application of 10% lidocaine spray should be avoided because of worsening of postoperative sore throat where incidence increased but not the severity in relation to 5% lidocaine gel. Applying 5% lidocaine on the endotracheal tube cuff does not prevent postoperative sore throat but its application is better than lidocaine 10% spray or saline.
-
Rev Bras Anestesiol · May 2016
[Colonoscopy sedation: clinical trial comparing propofol and fentanyl with or without midazolam].
Colonoscopy is one of the most common procedures. Sedation and analgesia decrease anxiety and discomfort and minimize risks. Therefore, patients prefer to be sedated when undergoing examination, although the best combination of drugs has not been determined. ⋯ Patients in Group II had a higher incidence of reaction (motor or verbal) to the colonoscope introduction, bradycardia, hypotension, and increased propofol consumption. Patient satisfaction was higher in Group I. According to the methodology used, the combination of midazolam, fentanyl, and propofol for colonoscopy sedation reduces propofol consumption and provides greater patient satisfaction.
-
Rev Bras Anestesiol · May 2016
[A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin].
Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. ⋯ In a manikin, the Airtraq and the McGrath laryngoscopes appeared superior to the Macintosh laryngoscope when dealing with simulated airway scenarios. Both devices were associated with better views, intubation times and rates of success, especially in a simulated "difficult airway". Overall satisfaction was highest with the McGrath laryngoscope. Similar clinical studies are needed.
-
Rev Bras Anestesiol · Mar 2016
[Total knee replacement induces peripheral blood lymphocytes apoptosis and it is not prevented by regional anesthesia - a randomized study].
Among the many changes caused by a surgical insult one of the least studied is postoperative immunosuppression. This phenomenon is an important cause of infectious complications of surgery such as surgical site infection or hospital acquired pneumonia. One of the mechanisms leading to postoperative immunosuppression is the apoptosis of immunological cells. Anesthesia during surgery is intended to minimize harmful changes and maintain perioperative homeostasis. The aim of the study was evaluation the effect of the anesthetic technique used for total knee replacement on postoperative peripheral blood lymphocyte apoptosis. ⋯ Peripheral blood lymphocyte apoptosis is an early event in the postoperative period lasts up to seven days and is not affected by the choice of the anesthetic technique.
-
Rev Bras Anestesiol · Mar 2016
[In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes].
Cuffs of tracheal tubes protect the lower airway from aspiration of gastric contents and facilitate ventilation, but may cause many complications, especially when the cuff pressure exceeds 30cm H2O. This occurs in over 30% of conventional insufflations, so it is recommended to limit this pressure. In this study we evaluated the in vitro effectiveness of a method of limiting the cuff pressure to a range between 20 and 30cm H2O. ⋯ This method was effective for inflating tracheal tube cuffs of different sizes and manufacturers, limiting its pressure to a range between 20 and 30cm H2O, with a success rate of 99.5% (95% CI: 99.1-99.9%).