Research report (Health Effects Institute)
-
Res Rep Health Eff Inst · Sep 2004
Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
This field evaluation study was conducted to assess new technology designed to measure number concentrations of strongly acidic ultrafine particles. Interest in these particles derives from their potential to cause adverse health effects. Current methods for counting and sizing airborne ultrafine particles cannot isolate those particles that are acidic. ⋯ In general, concentrations of ultrafine particles determined by AFM analysis of the detectors in the MOI-EAS and UDM appeared to underestimate the total number concentration as determined by comparison samplers. The ability to monitor airborne acidic particles provided by these iron nanofilm detectors enlarges the array of air quality variables that can be measured. This may help to resolve some of the outstanding questions related to causal relations between demonstrated health effects of ambient particles and particulate matter (PM) components.