The Journal of extra-corporeal technology
-
J Extra Corpor Technol · Mar 2013
Clinical TrialCorrelation of a novel noninvasive tissue oxygen saturation monitor to serum central venous oxygen saturation in pediatric patients with postoperative congenital cyanotic heart disease.
Using a novel noninvasive, visible-light optical diffusion oximeter (T-Stat VLS Tissue Oximeter; Spectros Corporation, Portola Valley, CA) to measure the tissue oxygen saturation (StO2) of the buccal mucosa, the correlation between StOz and central venous oxygen saturation (ScvO2) was examined in children with congenital cyanotic heart disease undergoing a cardiac surgical procedure. Paired StO2 and serum ScvO2 measurements were obtained postoperatively and statistically analyzed for agreement and association. Thirteen children (nine male) participated in the study (age range, 4 days to 18 months). ⋯ Statistical methods to control for repeatedly measuring the same subjects produced similar results. This study shows a moderate relationship and agreement between StO2 and ScvO2 measurements in pediatric patients with a history of congenital cyanotic heart disease undergoing a cardiac surgical procedure. This real-time monitoring device can act as a valuable adjunct to standard noninvasive monitoring in which serum SyvO2 sampling currently assists in the diagnosis of low cardiac output after pediatric cardiac surgery.
-
J Extra Corpor Technol · Mar 2013
Magnitude of arterial carbon dioxide change at initiation of extracorporeal membrane oxygenation support is associated with survival.
Many patient factors have been associated with mortality from extracorporeal membrane oxygenation (ECMO) therapy. Pre-ECMO patient pH and arterial carbon dioxide (paCO2) have been associated with poor outcome and can be significantly altered by ECMO initiation. We hypothesized that the magnitude of change in paCO2 and pH with ECMO initiation could be associated with survival. ⋯ After adjusting for potential confounders (age, use of epinephrine, volume of fluid administered, year of ECMO, ECMO indication, and duration of ECMO) by multivariable logistic regression, the magnitude of paCO2 change (> or =25 mmHg) was associated with mortality (adjusted OR, 2.21; 95% CI, 1.06-4.63; p = .036). The decrease in paCO2 with ECMO initiation was associated with mortality. Although this change in paCO2 is multifactorial, it represents a modifiable element of clinical management involving pre-ECMO ventilation, ECMO circuit priming, CO2 administration/removal, and may represent a future therapeutic target that could improve survival in pediatric ECMO.
-
J Extra Corpor Technol · Mar 2013
Plasma-free hemoglobin levels in advanced vs. conventional infant and pediatric extracorporeal life support circuits.
Extracorporeal life support (ECLS) is a reliable method to support pediatric patients with reversible cardiorespiratory failure associated with congenital heart disease, respiratory insufficiency, or after cardiac surgery. In 2010, our institution adopted an infant/pediatric extracorporeal membrane oxygenation (ECMO) circuit that contains a magnetically levitated centrifugal pump, polymethylpentene oxygenator, and shorter tubing length (ECMO II circuit). Our prior circuit contained a nonocclusive roller pump, polypropylene oxygenator, venous compliance chamber, and hemoconcentrator (ECMO I circuit). ⋯ There was also no significant difference in the group mean levels of PFH between ECMO I and ECMO II circuits. There was a significant increase in PFH with hours on ECMO (p < .01) within and between both circuit groups (p < .01) and a significantly greater increase in PFH with ECMO hours (p = .0091) in the ECMO I circuit group. Although there was no significant difference in average PFH with the change in ECMO II circuit technology, advancements such as the magnetically levitated blood pump and polymethylpentene gas exchange device has been associated with significantly fewer mechanical component change-outs (p = .0156) and less clots and fibrin build-up in the circuits (p = .0548).
-
J Extra Corpor Technol · Mar 2013
Extracorporeal membrane oxygenation: beneficial strategy for lung transplant recipients.
The role of extracorporeal membrane oxygenation (ECMO) as a therapeutic strategy has been very well documented for over a decade now with consistently positive remarks. The aim of the present study was analyzing the outcome of ECMO application in our lung transplant program, especially the feasibility and safety of our ECMO approach. Therefore, we retrospectively analyzed the data of 15 patients recipients requiring ECMO support. ⋯ At 28 days, the overall survival was 93% (14 of 15 patients) and 12 of these patients (80%) survived at least 6 months. Complications included acute renal insufficiency with temporary need of renal replacement therapy (53%), bleeding (33%), critical illness polyneuropathy (66%), and reversible thrombocytopenia (73%). Based on the evaluation of the patients in this analysis, ECMO seems to be a safe therapeutic approach in lung transplant recipients with severe respiratory failure directly after transplantation.
-
J Extra Corpor Technol · Mar 2013
Use of del Nido cardioplegia solution and a low-prime recirculating cardioplegia circuit in pediatrics.
The evolution of myocardial protection techniques has been both the source of milestone advancements and controversial debate in cardiac surgery. Our institution has modified a low-prime cardioplegia system (CPS) and adopted a single-dose cardioplegia solution (del Nido cardioplegia) for our congenital heart disease population. The goal of this article is to describe our CPS and outline our myocardial protection protocol. These techniques have allowed us to minimize circuit surface area, operate uninterrupted, and safely protect the myocardium during extended ischemic periods.