The Journal of extra-corporeal technology
-
J Extra Corpor Technol · Sep 2013
Practice GuidelineReport from AmSECT's International Consortium for Evidence-Based Perfusion: American Society of Extracorporeal Technology Standards and Guidelines for Perfusion Practice: 2013.
One of the roles of a professional society is to develop standards and guidelines of practice as an instrument to guide safe and effective patient care. The American Society of Extracorporeal Technology (AmSECT) first published its Essentials for Perfusion Practice, Clinical Function: Conduct of Extracorporeal Circulation in 1993. The International Consortium for Evidence-Based Perfusion (ICEBP), a committee within AmSECT, was tasked with updating this document in 2010. The aim of this report is to describe the method of development and content of AmSECT's new professional standards and guidelines. The ICEBP committee independently evaluated and provided input regarding the current "Essentials and Guidelines." Structural changes were made to the entire document, and a draft document was developed, presented, and circulated to the AmSECT Board of Directors and broader membership for comment. Informed by these reviews, a revised document was then presented to the Society for a membership vote. The final document consists of 15 areas of practice covered by 50 Standards and 38 Guidelines (see Appendix 1) with the first standard focusing on the development of institutional protocols to support their implementation and use. A majority of the membership voted to accept the document (81.2% of the voting membership accepting, 18.8% rejecting). After an audit of the balloting process by AmSECT's Ethics Committee, the results were reported to the membership and the document was officially adopted on July 24, 2013. The Standards and Guidelines will serve as a useful guide for cardiac surgical teams that wish to develop institution-specific standards and guidelines to improve the reliability, safety, and effectiveness of adult cardiopulmonary bypass. The ICEBP recognizes that the development of a Standards and Guidelines statement alone will not change care. Safe, reliable, and effective care will be best served through the development and implementation of institutional protocols based on these standards. AmSECT's Standards and Guidelines for Perfusion Practice reflect the changing landscape of our profession as we work toward a safer and optimal provision of cardiopulmonary bypass for all our patients as well as a work environment that is supportive of delivering this care. ⋯ standards, guidelines, cardiopulmonary bypass, perfusion, cardiac surgery.
-
J Extra Corpor Technol · Sep 2013
Randomized Controlled Trial Biography Historical Article Classical ArticleThe efficacy and safety of a pharmacologic protocol for maintaining coronary artery bypass patients at a higher mean arterial pressure during cardiopulmonary bypass. 1998.
-
J Extra Corpor Technol · Sep 2013
Regional variation in arterial saturation and oxygen delivery during venoarterial extracorporeal membrane oxygenation.
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) can be lifesaving in patients with cardiopulmonary collapse. However, observation studies have implied that oxygenated blood does not pass in a retrograde fashion from the VA-ECMO circuit to the aortic root and arch when the femoral artery (FA) is used. This study aims at accurately measuring the oxygen saturation in various arteries during VA-ECMO through different cannula sites. A total of 20 patients with VA-ECMO were in the study. Fourteen patients had FA cannulation, two patients received axillary arterial (AA) cannulation, and four patients received cannulation of the ascending aorta. Oxygen saturation was measured simultaneously in the radial artery and oxygenator outlet. In the patient group with FA cannulation, the oxygen saturation was lower in the radial artery (97%) when compared with the oxygenator outlet (> 99%). In the subset group of patients with severe lung dysfunction, oxygen saturation was even lower in the radial artery (73% saturation). In the patient group with AA cannulation, the oxygen saturation and partial oxygen pressure (PO2) in the oxygenator outlet and radial artery were similar (99% or greater). In the patient group with direct ascending aorta cannulation, the oxygen saturation and PO2 in the oxygenator outlet and radial artery were similar as well. Regional variations occur in the blood oxygen saturation depending on the site of the arterial cannulation in patients with VA-ECMO. With FA cannulation, the oxygen saturation in the radial artery is significantly lower than the one in the oxygenator outlet. This may imply that the coronaries and the brain receive hypoxic blood from the left ventricle. These results suggest that antegrade cannulation for VA-ECMO improves oxygen delivery to the proximal aorta distribution. ⋯ VA-ECMO, arterial oxygen saturation.