Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae
-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Apr 2008
[Effects of small volume resuscitation on the hemodynamics and extravascular lung water of septic shock dogs].
To observe the effect of small volume resuscitation by hypertonic-hyperoncotic solution on the hemodynamics and extravascular lung water of septic shock dogs. ⋯ All these four solutions can improve the hemodynamics of septic shock dogs. Small volume hypertonic-hyperoncotic solution has a similar effect in hemodynamics as NS, HS, and HES. Meanwhile, it does not increase the extravascular lung water.
-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Feb 2008
[Perioperative glycemic control by insulin glargine in type 2 diabetic patients].
To investigate the feasibility of perioperative glycemic control with insulin glargine in type 2 diabetic patients. ⋯ With satisfied fasting blood glucose level and fewer episode of hypoglycemia, perioperative glycemic control by insulin glargine in type 2 diabetic patients is safe, effective, and convenient.
-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Dec 2007
Comparative Study[Clinical observation of Cookgas intubating laryngeal airway in anticipating difficult tracheal intubation].
To compare the clinical effects of Cookgas intubating laryngeal airway (CILA) in facilitating fiberoptic bronchoscope (FOB) and Shikani optical stylet (SOS)-guided intubations in anticipating difficult tracheal intubation. ⋯ FOB and SOS-guided tracheal intubation via CILA is safe and effective in anticipating the outcome of difficult airway management. Compare to SOS-guided intubation, the time of FOB-guided intubation is shorter and the success rate is higher.
-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Oct 2007
Randomized Controlled Trial Comparative Study[Hemodynamic responses to orotracheal intubation with upsherscope or Macintosh direct laryngoscope].
To compare the hemodynamic responses to orotracheal intubation via Upsher-scope (USSP) or Macintosh direct laryngoscope (MDLS) under general anesthesia. ⋯ Orotracheal intubation using the USSP and MDLS may result in similar hemodynamic responses. The standard general anaesthesia can effectively inhibit the pressor, but not the tachycardiac responses caused by orotracheal intubation via USSP or MDLS. USSP is not superior than MDLS in palliating the adverse cardiovascular stress responses to orotracheal intubation.
-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Aug 2007
Randomized Controlled Trial[Protective endotracheal intubation to reduce endotracheal bacterial contamination].
To initially observe the effect of classical endotracheal intubation on endotracheal bacterial contamination and evaluate the validity of protective endotracheal intubation on reducing endotracheal bacterial contamination. ⋯ Endotracheal bacterial contamination may be caused by unprotective classical endotracheal intubation and could be reduced by protective endotracheal intubation.