Journal of diabetes science and technology
-
J Diabetes Sci Technol · Jan 2010
Multicenter StudyAccuracy of a new real-time continuous glucose monitoring algorithm.
Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG levels. ⋯ The Veo calibration algorithm, with sensor error reduced significantly in the 40- to 120-mg/dl range, improves hypoglycemia detection, while retaining accuracy at high glucose levels.
-
J Diabetes Sci Technol · Jan 2010
Clinical TrialMethods of evaluating the utility of continuous glucose monitor alerts.
The evaluation of continuous glucose monitor (CGM) alert performance should reflect patient use in real time. By evaluating alerts as real-time events, their ability to both detect and predict low and high blood glucose (BG) events can be examined. ⋯ Continuous glucose monitor alerts are capable of both detecting and predicting low and high BG events. The setting of alerts entails a trade-off between predictive ability and FA rate. Realistic analysis of this trade-off will guide patients in the effective utilization of CGM.
-
In 2007 a question was raised about the causal relationship between the first of the glucagon-like peptide 1 receptor agonists, exenatide, and pancreatitis, as postmarketing reports of pancreatitis in patients treated with this agent had been received by the Food and Drug Administration (FDA). There had been six reports of hemorrhagic pancreatitis, with two of the cases resulting in death. An update of the package insert for Byetta was mandated. ⋯ Of these, two cases have been hemorrhagic or necrotizing pancreatitis. A revision of the package insert for sitagliptin has been made recently. An examination of available data should help shed light on whether the relation is likely causal or merely incidental.
-
J Diabetes Sci Technol · Nov 2009
ReviewA review of perioperative glucose control in the neurosurgical population.
Significant fluctuations in serum glucose levels accompany the stress response of surgery or acute injury and may be associated with vascular or neurologic morbidity. Maintenance of euglycemia with intensive insulin therapy (IIT) continues to be investigated as a therapeutic intervention to decrease morbidity associated with derangements in glucose metabolism. ⋯ While extremes of glucose levels are to be avoided, there are little data to support specific use of IIT for maintenance of euglycemia in the perioperative management of neurosurgical patients. Existing data are summarized and reviewed in this context.
-
J Diabetes Sci Technol · Nov 2009
ReviewReducing glycemic variability in intensive care unit patients: a new therapeutic target?
Acute hyperglycemia is common in critically ill patients. Strict control of blood glucose (BG) concentration has been considered important because hyperglycemia is associated independently with increased intensive care unit mortality. After intensive insulin therapy was reported to reduce mortality in selected surgical critically ill patients, lowering of BG levels was recommended as a means of improving patient outcomes. ⋯ Several studies have confirmed significant associations between variability of BG levels and patient outcomes. Decreasing the variability of the BG concentration may be an important dimension of glucose management. If reducing swings in the BG concentration is a major biologic mechanism behind the putative benefits of glucose control, it may not be necessary to pursue lower glucose levels with their attendant risk of hypoglycemia.