International journal of clinical monitoring and computing
-
Int J Clin Monit Comput · Nov 1997
WCALive: broadcasting a major medical conference on the Internet.
Live video and sound from the 11th World Congress of Anaesthesiology in Sydney, Australia were broadcast over the Internet using the CuSeeme software package as part of an ongoing evaluation of Internet-based telecommunication in the delivery of Continuing Medical Education (CME). This was the first time such a broadcast had been attempted from a medical convention. The broadcast lasted for four days, during which a functioning combination of computer hardware and software was established. ⋯ Video reception was less successful for those receiving the broadcast via a modem based Internet connection. The received signal in such circumstances was adequate to provide a video presence of the speaker but inadequate to allow details of 35 mm slides to be visualised. We conclude that this technology will be of use in the delivery of CME materials to remote areas provided simultaneous viewing of high resolution still images is possible using another medium, such as the World Wide Web.
-
Int J Clin Monit Comput · Nov 1997
Auscultation revisited: the waveform and spectral characteristics of breath sounds during general anesthesia.
Although auscultation is commonly used as a continuous monitoring tool during anesthesia, the breath sounds of anesthetized patients have never been systematically studied. In this investigation we used digital audio technology to record and analyze the breath sounds of 14 healthy adult patients receiving general anesthesia with positive pressure ventilation. Sounds recorded from inside the esophagus were compared to those recorded from the surface of the chest, and corresponding airflow was measured with a pneumotachograph. ⋯ The peak frequency (Hz) was significantly higher in the esophageal recordings than the precordial samples (298 +/- 9 vs 181 +/- 10, P < 0.0001), as was the 97% spectral edge (Hz) (740 +/- 7 vs 348 +/- 16, P < 0.0001). In the adult population esophageal stethoscopes yield higher frequencies and greater amplitude than precordial stethoscopes. Quantification of lung sounds may provide for improved monitoring and diagnostic capability during anesthesia and surgery.
-
Int J Clin Monit Comput · Nov 1997
Respiratory sinus arrhythmia during anaesthesia: assessment of respiration related beat-to-beat heart rate variability analysis methods.
Beat-to-beat heart rate variability analysis is a powerful tool for the diagnosis of neuropathy. Respiration-related heart rate variability (respiratory sinus arrhythmia, RSA) reflects the function of parasympathetic nervous system during spontaneous ventilation while awake. RSA is also claimed to monitor the depth of anaesthesia. ⋯ Furthermore we confirmed that in addition to the amplitude, also the pattern of respiratory sinus arrhythmia is of interest: the pattern is reversed in phase compared to spontaneous breathing while awake, as we have shown earlier. To analyse RSA during anaesthesia, we recommend the use of an average phase RSA method based on beat-to-beat variability that shows both the amplitude and pattern of RSA. Finally, no measure of RSA should be used without a presentation of the actual beat-to-beat heart rate curve.