Frontiers in surgery
-
Frontiers in surgery · Jan 2016
ReviewOpen and Laparo-Endoscopic Repair of Incarcerated Abdominal Wall Hernias by the Use of Biological and Biosynthetic Meshes.
Although recently published guidelines recommend against the use of synthetic non-absorbable materials in cases of potentially contaminated or contaminated surgical fields due to the increased risk of infection (1, 2), the use of bio-prosthetic meshes for abdominal wall or ventral hernia repair is still controversially discussed in such cases. Bio-prosthetic meshes have been recommended due to less susceptibility for infection and the decreased risk of subsequent mesh explantation. The purpose of this review is to elucidate if there are any indications for the use of biological and biosynthetic meshes in incarcerated abdominal wall hernias based on the recently published literature. ⋯ Currently, there is a very limited evidence for the use of biological and biosynthetic meshes in strangulated hernias in either open or laparo-endoscopic repair. Finally, there is an urgent need to start with randomized controlled comparative trials as well as to support registries with data to achieve more knowledge for tailored indication for the use of biological meshes.
-
Frontiers in surgery · Jan 2016
ReviewPrevention of Incisional Hernias with Biological Mesh: A Systematic Review of the Literature.
Prophylactic mesh-augmented reinforcement during closure of abdominal wall incisions has been proposed in patients with increased risk for development of incisional hernias (IHs). As part of the BioMesh consensus project, a systematic literature review has been performed to detect those studies where MAR was performed with a non-permanent absorbable mesh (biological or biosynthetic). ⋯ There is no evidence supporting the use of non-permanent absorbable mesh (biological or biosynthetic) for prevention of IHs when closing a laparotomy in high-risk patients or in stoma reversal wounds. There is no evidence that a non-permanent absorbable mesh should be preferred to synthetic non-absorbable mesh, both in clean or clean-contaminated surgery.
-
Frontiers in surgery · Jan 2016
ReviewStereotactic Laser Ablation for Medically Intractable Epilepsy: The Next Generation of Minimally Invasive Epilepsy Surgery.
Epilepsy is a common, disabling illness that is refractory to medical treatment in approximately one-third of patients, particularly among those with mesial temporal lobe epilepsy. While standard open mesial temporal resection is effective, achieving seizure freedom in most patients, efforts to develop safer, minimally invasive techniques have been underway for over half a century. Stereotactic ablative techniques, in particular, radiofrequency (RF) ablation, were first developed in the 1960s, with refinements in the 1990s with the advent of modern computed tomography and magnetic resonance-based imaging. ⋯ The present review describes the original stereotactic ablation trials, followed by modern imaging-guided RF ablation series for mesial temporal lobe epilepsy. The developments of LITT and MRI thermometry are then discussed. Finally, the two currently available MRI-guided LITT systems are reviewed for their role in the treatment of mesial temporal lobe and other medically refractory epilepsies.
-
Frontiers in surgery · Jan 2016
Point-of-View Recording Devices for Intraoperative Neurosurgical Video Capture.
The ability to record and stream neurosurgery is an unprecedented opportunity to further research, medical education, and quality improvement. Here, we appraise the ease of implementation of existing point-of-view devices when capturing and sharing procedures from the neurosurgical operating room and detail their potential utility in this context. ⋯ The present study suggests that neurosurgical video capture and live streaming represents an opportunity to contribute to research, education, and quality improvement. Despite this promise, shortcomings render existing devices impractical for serious consideration. We describe the features that future recording platforms should possess to improve upon existing technology.
-
Frontiers in surgery · Jan 2016
Delayed Gastric Emptying after Pancreatic Surgery: Analysis of Factors Determinant for the Short-term Outcome.
Delayed gastric emptying (DGE) frequently complicates pancreatoduodenectomy (PD). Mainly DGE develops as consequence of postoperative intra-abdominal complications (secondary), while the incidence of primary DGE (i.e., not related to surgical complications) has rarely been studied. Moreover, the pathogenesis of DGE is complex and needs to be further elucidated. The present study aimed at highlighting potential mechanisms behind primary and above all secondary DGE by studying a variety of different pancreatic surgical procedures. ⋯ DGE is frequently seen after different surgical procedures directed toward the pancreatic gland. DGE is most commonly seen after PD, and half of these cases are scored as primary DGE. Primary and secondary DGE are seen in one-quarter of the cases even after pancreatic tail resection emphasizing the complex nature of the pathogenesis. Resection of the duodenum as an important mechanism behind DGE is not supported by the present results.