African journal of medicine and medical sciences
-
A 60-year old man with intracranial space occupying lesion, presented with difficulty in intubation at induction of anaesthesia. Several attempts at direct tracheal intubation were made until the airway was finally secured. ⋯ He presented for re-operation with worse signs of raised intracranial pressure which may accompany repeated attempts at intubation, a planned translaryngeal guided intubation was employed to secure the airway. Where fibreoptic laryngoscope is unavailable and difficult tracheal intubation is envisaged, translaryngeal guided intubation may save time and reduce morbidity of prolonged and repeated attempts at tracheal intubation.