Journal of the American Heart Association
-
Background Both drug-coated balloon (DCB) angioplasty and conventional plain balloon angioplasty (PBA) can be implemented to treat hemodialysis dysfunction. The present study aims to compare the safety and efficacy of these 2 approaches by conducting a meta-analysis of available randomized controlled trials. Methods and Results PubMed, Cochrane Library, and Embase databases were queried from establishment to January 2021. ⋯ The OR of mortality was comparable between 2 groups at 6 months (OR, 1.18; 95% CI, 0.42-3.33 [P=0.760]) and 1 year (OR, 0.93; 95% CI, 0.58-1.48 [P=0.750]). Conclusions Based on evidence from 18 randomized controlled trials, DCB angioplasty is superior to PBA in maintaining target lesion primary patency and circuit patency among patients with dialysis circuit stenosis. DCB angioplasty also reduces target lesion revascularization with a similar risk of mortality compared with PBA.