Quantification of left to right shunt in patent ductus arteriosus by color Doppler.
Ultrasound is a reliable tool to diagnose patent ductus arteriosus in premature infants but no reliable noninvasive method exists to quantify ductal flow. The aim of this study was to quantify the size of the shunt via persistent ductus arteriosus from pixel counts in color Doppler flow images. A cotton band was placed around the ductus arteriosus of newborn lambs to adjust the magnitude of flow. ⋯ When Qp/Qs was >1.4:1, more than 40% of the area in PALS in diastole exhibited color information. Similarly, the color pixel velocities squared correlated with the size of the shunt. Quantification of the percentage of pixels in a color Doppler registration via a computer-based analysis shows a high correlation with the size of ductal shunting.