Review Meta AnalysisUltrasonographic measurement of the respiratory variation in the inferior vena cava diameter is predictive of fluid responsiveness in critically ill patients: systematic review and meta-analysis.
Respiratory variation in the inferior vena cava (ΔIVC) has been extensively studied with respect to its value in predicting fluid responsiveness, but the results are conflicting. This systematic review was aimed at investigating the diagnostic accuracy of ΔIVC in predicting fluid responsiveness. Databases including Medline, Embase, Scopus and Web of Knowledge were searched from inception to May 2013. ⋯ The diagnostic performance of ΔIVC appeared to be better in patients on mechanical ventilation than in spontaneously breathing patients (DOR: 30.8 vs. 13.2). The pooled area under the receiver operating characteristic curve was 0.84 (95% CI: 0.79-0.89). Our study indicates that ΔIVC measured with point-of-care ultrasonography is of great value in predicting fluid responsiveness, particularly in patients on controlled mechanical ventilation and those resuscitated with colloids.