Thorax
-
Breathlessness leading to exercise limitation is common in patients with advanced cancer and is ineffectively treated. There are few research data to guide clinicians on best practice. The shuttle walking test has been validated for some conditions such as chronic obstructive pulmonary disease but not for advanced cancer. One of the well documented difficulties of doing clinical research in palliative care is the acceptability of assessment tests. This study examined the reproducibility of the shuttle walking test in patients with advanced cancer to help facilitate the systematic evaluation of interventions designed to improve breathlessness. ⋯ The shuttle walking test is a reproducible test of functional capacity in ambulant patients with advanced cancer, WHO performance status 1 or 2. The data indicate that a practice session is needed. It is easy to carry out and acceptable for patients with advanced cancer.