The American journal of gastroenterology
-
Am. J. Gastroenterol. · Sep 2006
Randomized Controlled TrialLevofloxacin-based triple therapy in first-line treatment for Helicobacter pylori eradication.
The standard first-line therapies for Helicobacter pylori eradication are based on clarithromycin and amoxicillin or metronidazole. Recent studies suggested levofloxacin as an alternative option for both first-and second-line H. pylori eradication treatment. ⋯ A 7-day levofloxacin-based triple therapy can achieve higher H. pylori eradication rates than standard regimens. These data suggest levofloxacin-based regimens can be the most effective in first-line anti-H. pylori therapy, at least in the Italian population.
-
Am. J. Gastroenterol. · Sep 2006
ReviewInconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
Endoscope reprocessing is a multi-stepped process that renders a contaminated endoscope safe for reuse. Its steps include meticulous cleaning, complete immersion in a liquid chemical sterilant (LCS) or disinfectant to achieve high-level disinfection (or "liquid sterilization"), water rinsing, and proper handling and storage. Surveys and reports indicate that not all health-care facilities dry their endoscopes after reprocessing. Endoscope drying can be easily, quickly, and inexpensively achieved by flushing the endoscope's internal channels, and wiping its external surfaces, with 70-90% ethyl or isopropyl alcohol, to facilitate drying after reprocessing, followed by compressed or forced air. ⋯ The finding that several guidelines are inconsistent with one another and that some are remiss and fail to recommend endoscope drying is of concern. Endoscope drying is as important to the prevention of nosocomial infection as cleaning and high-level disinfection (or "liquid sterilization"). Whereas wet or inadequately dried endoscopes pose an increased risk of contamination and have been associated with transmission of waterborne microorganisms and nosocomial infection, thoroughly dried (and properly cleaned and high-level disinfected) endoscopes have not been linked to nosocomial infection. Moreover, inconsistent guidelines can confuse reprocessing staff members and result in noncompliance, variations in the standard of care, and ineffective reprocessing. To minimize the risk of disease transmission and nosocomial infection, modification and revision of guidelines are recommended as required to be consistent with one another and to unconditionally recommend endoscope drying after completion of every reprocessing cycle, both between patient procedures and before storage, no matter the label claim of the LCS or disinfectant, the label claim of the automated reprocessing system, or the microbial quality of the rinse water. According to the medical literature, adoption of this recommendation may reduce the importance of not only monitoring the microbial quality of the rinse water, but also reprocessing endoscopes before the first patient of the day, both of which can be costly practices that a few guidelines recommend.
-
Am. J. Gastroenterol. · Sep 2006
Randomized Controlled TrialEfficacy of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy: a randomized controlled trial.
Bispectral (BIS) monitoring provides an objective, non-invasive measure of the level of consciousness in sedated patients. BIS has been shown to lag behind the level of sedation during induction and emergence of sedation with propofol. In this study, we sought to determine whether BIS is a useful adjunctive maneuver to registered nurse-administered propofol sedation (NAPS) as measured by reductions in recovery time and doses of propofol administered. ⋯ BIS did not lead to reductions in mean propofol dose or recovery time when used as an adjunct to NAPS for colonoscopy, or when used as the primary target for sedation. No clinically important role for BIS monitoring as an adjunct to NAPS has yet been established.
-
Am. J. Gastroenterol. · Sep 2006
Comparative StudyAssociation between achalasia and nitric oxide synthase gene polymorphisms.
Our group previously reported the absence of nitric oxide synthase (NOS) in the gastroesophageal junction of patients with achalasia. NOS exists in three distinct isoforms: neuronal NOS (nNOS), endothelial NOS (eNOS), and inducible isoform (iNOS). Some studies have shown that NO production is regulated by NOS polymorphisms. ⋯ Our data suggest that NOS gene polymorphisms are not involved in the susceptibility to and nature of the clinical course of sporadic achalasia. However, studies in a greater number of patients are required to analyze the tendency toward a higher prevalence of genotypes iNOS22*A/A and eNOS*4a4a.
-
Am. J. Gastroenterol. · Sep 2006
Editorial Comment Comparative StudySedation for endoscopic procedures: not as simple as it seems.
The Bispectral Index (BIS) is a processed electroencephalogram, which has been evaluated as an automated monitoring technique for patients receiving sedation for endoscopic procedures. BIS monitoring has not been shown to be of significant clinical benefit, but the need for an objective quantitative measure of the depth of sedation in patients undergoing endoscopy remains.