International journal of critical illness and injury science
-
Int J Crit Illn Inj Sci · Apr 2015
Dynamic behavior of venous collapsibility and central venous pressure during standardized crystalloid bolus: A prospective, observational, pilot study.
Measurement of intravascular volume status is an ongoing challenge for physicians in the surgical intensive care unit (SICU). Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications. Sonographic assessment of the collapsibility of the inferior vena cava (IVC) has been described as a noninvasive method for determining volume status. The purpose of this study was to analyze the dynamic response in IVC collapsibility index (IVC-CI) to changes in CVP in SICU patients receiving fluid boluses for volume resuscitation. ⋯ Observable changes in both VCI and CVP are apparent during an infusion of a standardized fluid bolus. Dynamic changes in VCI as a measurement of responsiveness to fluid bolus are inversely related to changes seen in CVP. Moreover, an IV bolus tends to produce an early response in VCI, while the CVP response is more gradual. Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation. Further studies with larger sample sizes are warranted.