European journal of nuclear medicine
-
Comparative Study
Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients.
The aim of this study was to evaluate the diagnostic value of technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy (HMPAO-LS) by means of a retrospective review of 116 patients divided into three groups of bone and joint infection. One hundred and thirty-one LS examinations were performed, and 143 sites analysed. The final diagnosis of infection was based on surgical, histological and bacteriological data and follow-up. ⋯ In group 3 (18 patients suspected of septic arthritis) there were eight true-positives, two false-negatives, ten true-negatives and two false-positives. Overall sensitivity of 99mTc-HMPAO-LS for the detection of bone and joint infection was 95%, with a specificity of 90% (group 1: sensitivity 97%, specificity 89%; group 2: 100% and 100%; group 3: 80% and 83%). It may be concluded that HMPAO-LS is an effective tool for the diagnosis of both bone infection involving implants and chronic osteomyelitis.