Acta orthopaedica Scandinavica. Supplementum
-
Acta Orthop Scand Suppl · Oct 2000
ReviewAlternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.
In allowing compression along the femoral shaft (uniaxial dynamization) and optional compression along the femoral neck (biaxial dynamization), the Medoff sliding plate (MSP) represents a new principle in the fixation of trochanteric hip fractures. The Twin hook with 2 apical hooks was designed as an alternative to the lag screw. In 3 prospective consecutive case series and 1 prospective randomized study together comprising 342 trochanteric fractures, these alternative techniques were investigated. 3 postoperative fixation failures occurred in the unstable intertrochanteric fractures treated with biaxial dynamization with the MSP (n = 194), and 5 in those treated with the sliding hip screw (n = 62) (p = 0.04). ⋯ Biaxial dynamization with the MSP appears to control fracture impaction effectively and minimizes the rate of postoperative fixation failure in intertrochanteric fractures. In subtrochanteric fractures, uniaxial dynamization prevents medialization of the femoral shaft and is therefore preferred to biaxial dynamization. The Twin hook appears to provide adequate fixation stability, and with potential for simplified intraoperative handling and reduced dissection, the Twin hook may pose advantages compared to the lag screw.