British heart journal
-
Eleven patients were studied and a total of 144 Wenckebach cycles in the AV node and 118 Wenckebach cycles in the His-Purkinje system were analysed to determine the incidence of typical and atypical Wenckebach periodicity, with particular emphasis on one variant of atypical Wenckebach that may simulate a Mobitz type II block. This pseudo-Mobitz II pattern was defined as a long Wenckebach cycle in which, at least, the last three beats of the cycle show relatively constant PR intervals (variation of no more than 0.02 s in surface leads and no more than 10 ms in His bundle electrograms) and in which the PR interval immediately following the blocked beat is shorter than the PR interval before the block by 0.04 s or more. ⋯ The pseudo-Mobitz II pattern was seen in 19 per cent of atypical AV nodal Wenckebach periods and in 17 per cent of atypical His-Purkinje system Wenckebach cycles. The need to discern a 'classical' Mobitz II block from a pseudo-Mobitz II pattern, especially in the setting of an acute inferior myocardial infarction, is emphasised.