Comparative StudyAdvantage of rubber over plastic endotracheal tubes for rapid extubation in a laser fire.
The occurrence of airway fires during laser airway surgery necessitates the use of special techniques to improve patient safety. For example, it is recommended that the endotracheal tube cuff be inflated with saline. However, in the event of an endotracheal tube fire, the tube must be quickly removed. ⋯ The mean times for each of the 3 groups were significantly different (p < 0.05) from each other as determined by the ANOVA. This study shows that if PVC endotracheal tubes are used, deflation of the saline-filled cuff by aspiration with a 10-ml syringe is faster than cutting the pilot tube. Unclamping the pilot tube on the RR endotracheal tubes resulted in the fastest time to endotracheal extubation.