Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
-
Cardiac resynchronization therapy has been shown to improve systolic function in patients with advanced chronic heart failure and electromechanical delay (QRS width > 120 ms). However, the effect of acute biventricular (BiV) pacing on perioperative haemodynamic changes is not well defined. In the present study, acute changes in regional left ventricular (LV) systolic function determined by tissue Doppler imaging (TDI) and global LV systolic function determined by the continuous cardiac output method were measured during various pacing configurations in patients with depressed LV systolic function undergoing heart surgery. ⋯ There were no differences in QRS duration during intrinsic rhythm, RA-BiV pacing, and AAI pacing. However, RA-LV and RA-RV stimulations showed a longer QRS duration (P < 0.01 vs. intrinsic rhythm, RA-BiV pacing, and AAI, respectively). Tissue Doppler velocities of the septal and lateral mitral annulus were comparable in all pacing modes. Neither CI nor PAP or PCW showed significant differences during the various pacing configurations. There was a positive correlation between regional (TDI) and global (CI) parameters of LV systolic function. Conclusions Biventricular pacing after heart surgery does not improve parameters of regional and global LV systolic function acutely in patients with heart failure and intraventricular conduction delay and, thus, may not reflect changes observed with chronic BiV pacing.
-
To describe a patient showing monomorphic ventricular tachycardia, ECG aspect of Brugada syndrome, and structural heart abnormalities due to a homozygous missense mutation in SCN5A. ⋯ This study provides the first evidence of a homozygous missense mutation in SCN5A associated with atypical ventricular arrhythmias and right structural abnormalities.
-
Within the last several years, transvenous cryo-ablation has become an alternative method to perform ablation of the slow-pathway. This study evaluated the acute and long-term safety and effectiveness of atrio-ventricular nodal re-entrant tachycardia (AVNRT) cryo-ablation. ⋯ Slow pathway cryo-ablation is associated with an acute success but a higher recurrence rate. A 6-mm-tip cryo-catheter seems to assure during cryo-ablation a large acute and long-term success. AV-block seems non-guaranteed by a negative cryo-mapping, stressing on need of a careful surveillance. Nevertheless, the theoretical advantage of avoiding the risk of permanent AV-block when compared with radiofrequency needs larger series to be demonstrated.