Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
-
Multicenter Study Comparative Study
Intracardiac impedance monitors stroke volume in resynchronization therapy patients.
Monitoring of haemodynamic parameters or surrogate parameters of the left ventricle is especially important for patients under cardiac resynchronization therapy (CRT). Intracardiac impedance reflects left ventricular (LV) volume changes well in animal models. Since it is unknown whether this also holds in humans with heart failure (HF), we examined the correlation of LV intracardiac impedance with haemodynamic parameters in CRT patients for different positions of the LV lead. ⋯ In HF patients, a strong correlation between changes in intracardiac impedance and LV SV was found. Typical LV lead implant positions have been tested and all appear to be suitable for this method of LV volume monitoring.
-
Comparative Study
Oesophageal temperature monitoring and incidence of oesophageal lesions after pulmonary vein isolation using a remote robotic navigation system.
Oesophageal lesions (EL), a potential complication after pulmonary vein isolation (PVI), have been described recently. A new remote robotic navigation system (RNS; Hansen Medical) provides enhanced catheter stability along with more effective lesion placement. The aim of this prospective study was to evaluate temperature monitoring and incidence of EL when using RNS with an irrigated tip radiofrequency catheter for PVI. ⋯ In patients undergoing PVI using the RNS, the incidence of EL is 14.3% when using power settings comparable to settings used in manual ablation. Patients with lower BMI (<26) are at higher risk for EL.
-
Heart failure patients are often equipped with implanted devices and are frequently hospitalized due to volume overload. Reliable prediction of imminent fluid congestion has the potential to provide early detection of cardiac decompensation and therefore might be capable of enhancing therapy management. We investigated whether implant-based impedance (Z) measurement is closely correlated with directly assessed extravascular lung water and might thus be useful for patient monitoring. ⋯ Changes of Z show a strong inverse correlation with changes of directly measured EVLWI. This allows the application of Z as a measure of intrathoracic fluid status and has the potential to optimize patient care, especially in the context of evolving telemedicine concepts.