The neuroradiology journal
-
Based on past laboratory and anecdotal clinical experience, we hypothesized that prolonged cervical spinal cord stimulation (SCS) in the acute settings of aneurysmal subarachnoid hemorrhage (aSAH) would be both safe and feasible, and that 2-week stimulation will reduce incidence of cerebral arterial vasospasm. The goal of our clinical study was to establish feasibility and safety of cervical SCS in a small group of selected aSAH patients. Single-arm non-randomized prospective study of cSCS in aSAH patients involved percutaneous implantation of 8-contact electrode in 12 consecutive aSAH patients that satisfied strict inclusion criteria. ⋯ Our study of SCS for prevention of vasospasm after aSAH conclusively shows both safety and feasibility of this promising treatment approach. Despite high level of acuity in aSAH patients, impaired level of consciousness, frequent patient re-positioning, need in multiple tests and variety of monitors, SCS electrodes may be safely implanted and maintained for the two-week period. Long-term follow up shows no adverse effects of cervical SCS in this patient category.
-
The aim of this paper is to analyse the pathophysiology of 3 DVA cases from our institution, review the literature and propose a classification of these lesions. ⋯ We postulate that the arteriovenous shunting resulted in arterial steal and chronic hypoxia which could be a pathophysiological mechanism for symptomatic DVAs. CTP and 4D CTA are effective non invasive tools to study DVAs. A classification is proposed.
-
To compare the accuracy of a three dimensional, T2-weighted double inversion recovery (DIR) sequence with two dimensional fluid attenuated inversion recovery (FLAIR) and dual echo T2 (DE T2) sequences at 3 Tesla in the detection of intracranial demyelinating lesions in patients with known or suspected multiple sclerosis (MS), and to consider the appropriateness of a stand-alone DIR sequence in MS imaging. The studies of 98 patients who underwent imaging with DE T2, FLAIR and DIR sequences for known or suspected multiple sclerosis were retrospectively reviewed. In 42 cases, a diagnosis of MS had been clinically suspected. ⋯ At 3 Tesla, a T2 weighted, three dimensional DIR sequence is as accurate at detecting the presence of intracranial demyelinating lesions as two dimensional FLAIR and DE T2 sequences combined. A greater number of lesions were detected with the DIR sequence, and all lesions were more conspicuous. A single, stand alone DIR sequence may be considered appropriate for monitoring MS.