Journal of surgical case reports
-
This report discusses the use of an alternative implant in the emergency fixation of a distal tibial fracture. We planned to fix the shear-type medial malleolar fracture in a closed, tri-malleolar fracture with a locking distal tibial plate. Intra-operatively, it was noted that the required plate was unavailable. ⋯ Despite adequate planning, there will be instances where one has to improvise. An understanding of the principles of fracture management can aid in finding solutions. PHILOS humeral plate may be used to stabilize a distal tibial fracture if an appropriate distal tibial locking plate is not available.