American journal of physiology. Heart and circulatory physiology
-
A novel framework of circulatory equilibrium was developed by extending Guyton's original concept. In this framework, venous return (CO(V)) for a given stressed volume (V) was characterized by a flat surface as a function of right atrial pressure (P(RA)) and left atrial pressure (P(LA)) as follows: CO(V) = V/W - G(S)P(RA) - G(P)P(LA), where W, G(S), and G(P) denote linear parameters. In seven dogs under total heart bypass, CO(V), P(RA), P(LA), and V were varied to determine the three parameters in each animal with use of multivariate analysis. ⋯ In this way, we could predict CO [y = 0.90x + 5.6, r(2) = 0.95, standard error of the estimate (SEE) = 8.7 ml.min(-1).kg(-1)], P(RA) (y = 0.96x, r(2) = 0.98, SEE = 0.2 mmHg), and P(LA) (y = 0.89x + 0.5, r(2) = 0.98, SEE = 0.8 mmHg) reasonably well. We conclude that the venous return surface accurately represents the venous return properties of the systemic and pulmonary circulations. The characteristics of the venous return surface are invariable enough among animals, making it possible to predict circulatory equilibrium, even if those characteristics are unknown in individual animals.