American journal of physiology. Heart and circulatory physiology
-
Am. J. Physiol. Heart Circ. Physiol. · Jul 2005
Comparative StudyWave-energy patterns in carotid, brachial, and radial arteries: a noninvasive approach using wave-intensity analysis.
The study of wave propagation at different points in the arterial circulation may provide useful information regarding ventriculoarterial interactions. We describe a number of hemodynamic parameters in the carotid, brachial, and radial arteries of normal subjects by using noninvasive techniques and wave-intensity analysis (WIA). Twenty-one normal adult subjects (14 men and 7 women, mean age 44 +/- 6 yr) underwent applanation tonometry and pulsed-wave Doppler studies of the right common carotid, brachial, and radial arteries. ⋯ S-wave energy was greatest in the brachial artery (993.5 +/- 87.8 mJ/m2), but R-wave energy was greatest in the radial artery (176.9 +/- 19.9 mJ/m2). X-wave energy was significantly higher in the brachial and radial arteries (176.4 +/- 32.7 and 163.2 +/- 30.5 mJ/m2, respectively) compared with the carotid artery (41.0 +/- 9.4 mJ/m2; P < 0.001). WIA illustrates important differences in wave patterns between peripheral arteries and may provide a method for understanding ventriculo-arterial interactions in the time domain.
-
Am. J. Physiol. Heart Circ. Physiol. · Jul 2005
Arginine vasopressin reduces intestinal oxygen supply and mucosal tissue oxygen tension.
We investigated intestinal oxygen supply and mucosal tissue PO2 during administration of increasing dosages of continuously infused arginine vasopressin (AVP) in an autoperfused, innervated jejunal segments in anesthetized pigs. Mucosal tissue PO2 was measured by employing two Clark-type surface oxygen electrodes. Oxygen saturation of jejunal microvascular hemoglobin was determined by tissue reflectance spectrophotometry. ⋯ AVP infusion led to a significant (P < .05), dose-dependent decrease in cardiac index (from 121 +/- 31 to 77 +/- 27 ml.kg(-1).min(-1) at 0.229 IU.kg(-1).h(-1)) and systemic oxygen delivery (from 14 +/- 3 to 9 +/- 3 ml.kg(-1).min(-1) at 0.229 IU.kg(-1).h(-1)) concomitant with an increase in systemic oxygen extraction ratio (from 31 +/- 4 to 48 +/- 10%). AVP decreased microvascular blood flow (from 133 +/- 47 to 82 +/- 35 perfusion units at 0.114 IU.kg(-1).h(-1)), mucosal tissue PO2 (from 26 +/- 7 to 7 +/- 2 mmHg at 0.229 IU.kg(-1).h(-1)), and microvascular hemoglobin oxygen saturation (from 51 +/- 9 to 26 +/- 12% at 0.229 IU.kg(-1).h(-1)) without a significant increase in mesenteric venous lactate concentration (2.3 +/- 0.8 vs. 3.4 +/- 0.7 mmol/l). We conclude that continuously infused AVP decreases intestinal oxygen supply and mucosal tissue PO2 due to a reduction in microvascular blood flow and due to the special vascular supply in the jejunal mucosa in a dose-dependent manner in pigs.
-
Am. J. Physiol. Heart Circ. Physiol. · Jul 2005
Prediction of circulatory equilibrium in response to changes in stressed blood volume.
Accurate prediction of cardiac output (CO), left atrial pressure (PLA), and right atrial pressure (PRA) is a prerequisite for management of patients with compromised hemodynamics. In our previous study (Uemura et al. Am J Physiol Heart Circ Physiol 286: H2376-H2385, 2004), we demonstrated a circulatory equilibrium framework, which permits the prediction of CO, PLA, and PRA once the venous return surface and integrated CO curve are known. ⋯ In another eight dogs, we altered stressed blood volume (-8 to +8 ml/kg of reference volume) under normal and heart failure conditions and predicted the hemodynamics by intersecting the surface and the CO curve thus estimated. We could predict CO [y = 0.93x + 6.5, r2 = 0.96, standard error of estimate (SEE) = 7.5 ml.min(-1).kg(-1)], PLA (y = 0.90x + 0.5, r2= 0.93, SEE = 1.4 mmHg), and PRA (y = 0.87x + 0.4, r2= 0.91, SEE = 0.4 mmHg) reasonably well. In conclusion, single-point estimation of the integrated CO curve enables accurate prediction of hemodynamics in response to extensive changes in stressed blood volume.