The journal of vascular access
-
Technical factors at the moment of catheter insertion might have a role in peripherally inserted central catheter-related thrombotic risk. We performed a systematic review and meta-analysis to define the actual rate of peripherally inserted central catheter-related symptomatic deep vein thrombosis in patients in whom catheter insertion was performed according to ultrasound guidance, appropriate catheter size choice, and proper verification of tip location. ⋯ A proper technique is crucial at the moment of peripherally inserted central catheter insertion. Peripherally inserted central catheter-related deep vein thrombosis rate appears to be low when evidence-based technical factors are taken into consideration during the insertion procedure.
-
The commonly preferred right internal jugular vein was investigated in terms of its dimensions, the relationship between its dimensions and anthropometric measures, and the outcomes of its cannulation in infants. Data regarding its position with respect to the carotid artery indicated anatomical variation. ⋯ Right internal jugular vein revealed a varying position with respect to carotid artery with a higher rate of lateral position. The presence of such anatomical variation requires ultrasonographic evaluation prior to interventions and real-time guidance during interventions involving right internal jugular vein.
-
The Infusional Services Team at a large cancer centre in Belfast, Northern Ireland, performed a cross-sectional analysis of two catheter securement technologies to address an area of frequent, but underestimated concern - peripherally inserted central catheter migration and dislodgement. Healthcare practitioner and patient feedback, along with economic impact, were assessed. The costs associated with catheter replacement during the adhesive device group study period were calculated using an average cost per insertion, based on material costs required for the procedure. ⋯ In the subcutaneous securement group, the material costs were adjusted for use of the subcutaneous device as it remained in situ for the duration of the catheters' dwell time. This review found that subcutaneous securement offers both patient and facilities a safe, effective and economical alternative for device securement with patients who are unable to tolerate or have successful securement with adhesive securement devices. The use of subcutaneous devices provided for reduced risks for peripherally inserted central catheters in terms of dislodgement, migration or malposition, alleviating the potential risks to develop catheter-related thrombosis and device-related infection.
-
In an effort to reduce catheter-related bloodstream infection's incidence rates in an intensive care unit, several evidence-based procedures recommended by the Centers for Disease Control and Prevention for centrally inserted central catheters were implemented. A failure to fully comply with the recommendation for prompt removal of the centrally inserted central catheters was attributed, mainly to the difficulties and inadequacies raised from establishing peripheral venous access. ⋯ The reduction of catheter-related bloodstream infection was higher than that described in the published literature. This probably shows that the combination of the five evidence-based procedures recommended by the Centers for Disease Control and Prevention together with that of ultrasound-guided peripheral venous cannulation method can increase the compliance with the Category IA recommendation for removal or avoidance of unnecessary placement of centrally inserted central catheters and decrease the catheter-related bloodstream infections in a more effective way, by affecting the patients' centrally inserted central catheter exposure.
-
Observational Study
Dynamic variation of the axillary veins due to intrathoracic pressure changes: A prospective sonographic study.
The ultrasound-guided axillary vein is becoming a compulsory alternative vessel for central venous catheterization and the anatomical position offers several potential advantages over blind, subclavian vein techniques. ⋯ Anatomical variations in depth and diameter as well as the collapsibility due to intrathoracic pressures changes represent common challenges that face clinicians during central venous catheterization of the axillary vein. A noteworthy increase in vessel size as patients transition from spontaneous to mechanical ventilation may theoretically improve first-pass cannulation success with practitioners skilled in both ultrasound and procedure. As a result, placing a centrally inserted central catheter after the induction of anesthesia may be beneficial.