Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors.
We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors. ⋯ As compared with 1.5T, 3T 1H MRS demonstrated 49-73% SNR increase in the cerebral metabolites and slightly superior spectral resolution only at a short TE, but little at an intermediate TE, in the brain tumors. There was no significant difference in the metabolite ratios between the two field strengths.
-
The purpose of this study was to demonstrate the ultrasonographic (US) findings of rupture and the healing process of the medial head of the gastrocnemius ("Tennis Leg"). ⋯ Ultrasonography is a useful imaging modality for the diagnosis and follow-up examination for the patients suffering with rupture of the medial head of the gastrocnemius.