The spine journal : official journal of the North American Spine Society
-
Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions. ⋯ This method avoids lateral shots of fluoroscopy during screw placement and thus decreases the operation time and exposes surgeons to less radiation. At the same time, compared with the computer-navigated procedure, it is less facility-demanding, and provides satisfactory reliability and accuracy.
-
Review Comparative Study
Intraoperative image guidance compared with free-hand methods in adolescent idiopathic scoliosis posterior spinal surgery: a systematic review on screw-related complications and breach rates.
Severe adolescent idiopathic scoliosis (AIS) is a three-dimensional spinal deformity requiring surgery to stop curve progression. Posterior spinal instrumentation and fusion with pedicle screws is the standard surgery for AIS curve correction. Vascular and neurologic complications related to screw malpositioning are concerns in surgeries for AIS. Breach rates are reported at 15.7%, implant-related complications at 1.1%, and neurologic deficit at 0.8%. Free-hand screw insertion remains the prevailing method of screw placement, whereas image guidance has been suggested to improve placement accuracy. ⋯ Although point estimates on breach rates are decreased with CT navigation compared with free-hand methods, complication rates remain conflicting between the two methods. Current evidence is limited by small sample sizes, lack of comparison groups, and poorly predefined complications. Randomized controlled trials with larger samples with standardized definitions and recording of predefined breach and complication occurrences are recommended.
-
Blood transfusions in spine surgery are shown to be associated with increased patient morbidity. The association between transfusion performed using a liberal hemoglobin (Hb) trigger-defined as an intraoperative Hb level of ≥10 g/dL, a postoperative level of ≥8 g/dL, or a whole hospital nadir between 8 and 10 g/dL-and perioperative morbidity and cost in spine surgery patients is unknown and thus was investigated in this study. ⋯ Transfusion using a liberal trigger is associated with increased morbidity, even after controlling for possible confounders. Our results suggest that modification of transfusion practice may be a potential area for improving patient outcomes and reducing costs.
-
Anterior cervical discectomy and fusion (ACDF) is a very common operative intervention for the treatment of cervical spine degenerative disease in those who have failed non-operative measures. However, studies examining long-term follow-up on patients who underwent ACDF reveal evidence of radiographic and clinical degenerative disc disease at the levels adjacent to the fusion construct. Consistent with other junctional regions of the spine, the cervicothoracic junction (CTJ) has significant morphologic variations. As a result, the CTJ undergoes significant static and dynamic stress. Given these findings, there has been some thought that ACDF down to C7 may experience additional risks for adjacent segment degeneration/disease (ASD) when compared with ASDFs that are cephalad to C7. ⋯ The cervicothoracic junction may present with vulnerability to ASD given the junctional biomechanics. However, this study provides evidence that an ACDF with the caudal level of C7 does not incur additional risk of ASD, showing similar outcomes to ACDFs at other levels.
-
Comparative Study
The use of a novel perfusion-based cadaveric simulation model with cerebrospinal fluid reconstitution comparing dural repair techniques: a pilot study.
Watertight dural repair is crucial for both incidental durotomy and closure after intradural surgery. ⋯ We described the feasibility of using a novel cadaveric model for both the study and training of watertight dural closure techniques. 6-0 Prolene was observed to be superior to 4-0 Nurolon for watertight dural closure without a hydrogel sealant. The use of a hydrogel sealant significantly improved watertight dural closures for both 6-0 Prolene and 4-0 Nurolon groups in the cadaveric model.