The spine journal : official journal of the North American Spine Society
-
Review Case Reports
Cervical myelopathy resulting from combined ossification of the ligamentum flavum and posterior longitudinal ligament: report of two cases and literature review.
In the cervical spine, the combination of ossification of the ligamentum flavum (OLF) and ossification of the posterior longitudinal ligament (OPLL) is rarely seen. There have been only four cases reported in the English literature. ⋯ We experienced two cases of cervical myelopathy resulting from the combination of OLF and OPLL in the cervical spine. The symptoms of myelopathy were treated successfully by laminectomy and laminoplasty with OLF resection in both cases. The literature review including the present two cases revealed that cervical OLF tended to occur adjacent or close to the margin of cervical OPLL, suggesting that the increased mechanical stress at the junction of OPLL may be a causative factor.
-
Comparative Study
Biomechanical evaluation of stand-alone lumbar polyether-ether-ketone interbody cage with integrated screws.
Stand-alone interbody cages with integrated screws potentially provide a biomechanically stable solution for anterior lumbar interbody fusion (ALIF) that alleviates the need for additional exposure for supplemental fixation, thereby reducing the chance of additional complications and morbidity. ⋯ Biomechanical testing revealed that the stand-alone cage with integrated screws provides more immediate stability than a cage alone and provides equivalent stability to ALIF constructs with supplemental fixation in lateral bending and axial rotation. Additional flexion-extension rigidity of the anterior cage maybe realized by the addition of a spinous process plate that was found to be as stable as supplemental bilateral PS.
-
Dural ectasia in the lumbosacral spine is a common feature of Marfan syndrome and is associated with low back pain and surgical complications, but its natural history is unknown. ⋯ During this 10-year period, the natural history of dural ectasia in adults with Marfan syndrome was not associated with a significant increase in ODI scores, dural ectasia size, or with the development/progression of spondylolisthesis or spondylolysis.
-
Comparative Study
Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis.
Recently, nonfusion pedicle-based dynamic stabilization systems (PBDSs) have been developed and used in the management of degenerative lumbar spinal diseases. Still effects on spinal kinematics and clinical effects are controversial. Little biomechanical information exists for providing biomechanical characteristics of pedicle-based dynamic stabilization according to the PBDS design before clinical implementation. ⋯ Implanted segments with PBDSs have limited ROM when compared with the intact spine. Center of rotation and stress distribution differed according to the design and materials used. These biomechanical effects produced a nonphysiological stress on the functional spinal unit when they were implanted. The biomechanical effects of current PBDSs should be carefully considered before clinical implementation.
-
Clinical Trial
Ten-year survival and clinical outcome of the AcroFlex lumbar disc replacement for the treatment of symptomatic disc degeneration.
We have previously reported on the osseointegration, stability, and preserved motion of the AcroFlex lumbar disc replacement (LDR) in a nonhuman primate model. Detailed biomechanical testing of the device predicted implant survival for at least 10 years of in vivo use. Significant improvements in the clinical outcome were reported at 2 years. However, mechanical failure of the polyolefin rubber was detected by fine-cut computed tomography (CT) in a number of subjects within 2 years. As a result, no further devices were implanted. ⋯ The cumulative survival was 60.7% at 10 years when the first revision surgery was taken as the end point. The etiology of the implant failure prompting the revision included failure of osseointegration, midsubstance elastomeric tears, and osteolysis. Further use of this implant is not justified. The incidence of adjacent-level disc degeneration for the AcroFlex was comparable with that observed adjacent to the spinal fusion. Salvage procedures involving conversion to spinal fusion are technically demanding, but appear to improve outcomes modestly.