-
Created October 27, 2018, last updated almost 4 years ago.
Collection: 93, Score: 915, Trend score: 0, Read count: 1132, Articles count: 7, Created: 2018-10-27 10:47:43 UTC. Updated: 2021-02-09 00:08:04 UTC.Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.
Collected Articles
-
Anesthesia and analgesia · Jan 2016
Randomized Controlled Trial Multicenter StudyA Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial.
Closed-loop systems for anesthesia delivery have been shown to outperform traditional manual control in different clinical settings. The present trial was aimed at evaluating the feasibility and efficacy of Bispectral Index (BIS)-guided closed-loop anesthesia delivery system (CLADS) in comparison with manual control across multiple centers in India. ⋯ Our study in a multicenter setting proves the consistently better performance of automated anesthesia drug delivery compared with conventional manual control. This highlights an important advantage of an automated system for delivering standardized anesthesia, thereby overcoming differences in practices among anesthesiologists.
-
Randomized Controlled Trial
Feasibility of Closed-loop Titration of Propofol and Remifentanil Guided by the Bispectral Monitor in Pediatric and Adolescent Patients: A Prospective Randomized Study.
Closed loop control of propofol/remi TIVA targeting BIS 40-60 is more precise than manual control.
pearl -
Multicenter Study Comparative Study Clinical Trial
Feasibility of closed-loop co-administration of propofol and remifentanil guided by the bispectral index in obese patients: a prospective cohort comparison†
Closed-loop delivery of total intravenous anesthesia with propofol and remifentanil, guided by BIS, is feasible in obese patients.
pearl -
Acta Anaesthesiol Scand · Mar 2009
Randomized Controlled Trial Comparative StudyComparison of closed loop vs. manual administration of propofol using the Bispectral index in cardiac surgery.
In recent years, electroencephalographic indices of anaesthetic depth have facilitated automated anaesthesia delivery systems. Such closed-loop control of anaesthesia has been described in various surgical settings in ASA I-II patients (1-4), but not in open heart surgery characterized by haemodynamic instability and higher risk of intra-operative awareness. Therefore, a newly developed closed-loop anaesthesia delivery system (CLADS) to regulate propofol infusion by the Bispectral index (BIS) was compared with manual control during open heart surgery. ⋯ The automated delivery of propofol using CLADS was safe, efficient and performed better than manual administration in open heart surgery.
-
Randomized Controlled Trial Multicenter Study
Closed-loop control better than open-loop control of profofol TCI guided by BIS: a randomized, controlled, multicenter clinical trial to evaluate the CONCERT-CL closed-loop system.
The CONCERT-CL closed-loop infusion system designed by VERYARK Technology Co., Ltd. (Guangxi, China) is an innovation using TCI combined with closed-loop controlled intravenous anesthesia under the guide of BIS. In this study we performed a randomized, controlled, multicenter study to compare closed-loop control and open-loop control of propofol by using the CONCERT-CL closed-loop infusion system. ⋯ The CONCERT-CL closed-loop infusion system can automatically regulate the TCI of propofol, maintain the BIS value in an adequate range and reduce the workload of anesthesiologists better than open-loop system.
-
J Clin Monit Comput · Feb 2014
Randomized Controlled TrialAutomated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.
Closed loop target-control infusion systems using a Bispectral (BIS) signal as an input (TCI Loop) can automatically maintain intravenous anesthesia in a BIS range of 40-60 %. Our purpose was to assess to what extent such a system could decrease anesthesia workload in comparison to the use of a stand alone TCI system manually adjusted to fit the same BIS range of 40-60 % (TCI Manual). Patients scheduled for elective vascular or thoracic surgery were randomized to the TCI Loop or TCI Manual method for administering propofol and remifentanil during both induction and maintenance of general anesthesia. ⋯ Mean arterial pressure was lower with TCI Manual (78 ± 6 vs. 88 ± 13 mmHg, p < 0.001). The number of times the anesthesiologist watched the controller or BIS monitor (p < 0.05) and the number of manual adjustments (p < 0.001) performed in each group was lower with TCI Loop group during induction and maintenance of anesthesia. An automated controller strikingly frees the anesthesiologist from manual intervention to adjust drug delivery.
-
Randomized Controlled Trial Comparative Study
Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor.
This randomized controlled trial describes automated coadministration of propofol and remifentanil, guided by M-Entropy analysis of the electroencephalogram. The authors tested the hypothesis that a novel dual-loop controller with an M-Entropy monitor increases time spent within predetermined target entropy ranges. ⋯ Intraoperative automated control of hypnosis and analgesia guided by M-Entropy is clinically feasible and more precise than skilled manual control.
- Simple formatting can be added to notes, such as