J Clin Monit Comput · Aug 2021
Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry.
- Ludvik Alkhoury, Ji-Won Choi, Chizhong Wang, Arjun Rajasekar, Sayandeep Acharya, Sean Mahoney, Barry S Shender, Leonid Hrebien, and Moshe Kam.
- Department of Electrical and Computer Engineering, Newark College of Engineering, New Jersey Institute of Technology, New Jersey, 07102, USA. La256@njit.edu.
- J Clin Monit Comput. 2021 Aug 1; 35 (4): 797813797-813.
AbstractCalculation of peripheral capillary oxygen saturation [Formula: see text] levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two [Formula: see text]-level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. These techniques are: (1) "Red over Infrared," calculating the ratios of AC and DC components of the red and infrared PPG signals,[Formula: see text], followed by the use of a calibration curve to determine the [Formula: see text] level Webster (in: Design of pulse oximeters, CRC Press, Boca Raton, 1997); and (2) a motion-resistant algorithm which uses the Discrete Saturation Transform (DST) (Goldman in J Clin Monit Comput 16:475-83, 2000). The DST algorithm isolates individual "saturation components" in the optical pathway, which allows separation of components corresponding to the [Formula: see text] level from components corresponding to noise and interference, including motion artifacts. The comparison we provide here (employing the two techniques with and without pre-filtering) addresses two aspects: (1) accuracy of the [Formula: see text] calculations; and (2) computational complexity. We used both synthetic data and experimental data collected from human subjects. The human subjects were tested at rest and while exercising; while exercising, their measurements were subject to the impacts of motion. Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the "Red over Infrared" approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between [Formula: see text]-level accuracy and computational complexity. A modest improvement in [Formula: see text] estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in [Formula: see text] level accuracy at -10 dB over unfiltered DST algorithm and the filtered "Red over Infrared" approach). However, this improvement comes at a significant computational cost.© 2020. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.