• J Biomed Inform · Nov 2018

    A novel depth estimation algorithm of chest compression for feedback of high-quality cardiopulmonary resuscitation based on a smartwatch.

    • Tsung-Chien Lu, Yi Chen, Te-Wei Ho, Yao-Ting Chang, Yi-Ting Lee, Yu-Siang Wang, Yen-Pin Chen, Chia-Ming Fu, Wen-Chu Chiang, Matthew Huei-Ming Ma, Cheng-Chung Fang, Feipei Lai, and Anne M Turner.
    • Dept. of Emergency Medicine, National Taiwan University Hospital, Taipei, Taiwan; Dept. of Biomedical Informatics and Medical Education, University of Washington, Seattle, United States.
    • J Biomed Inform. 2018 Nov 1; 87: 60-65.

    IntroductionHigh-quality cardiopulmonary resuscitation (CPR) is a key factor affecting cardiac arrest survival. Accurate monitoring and real-time feedback are emphasized to improve CPR quality. The purpose of this study was to develop and validate a novel depth estimation algorithm based on a smartwatch equipped with a built-in accelerometer for feedback instructions during CPR.MethodsFor data collection and model building, researchers wore an Android Wear smartwatch and performed chest compression-only CPR on a Resusci Anne QCPR training manikin. We developed an algorithm based on the assumptions that (1) maximal acceleration measured by the smartwatch accelerometer and the chest compression depth (CCD) are positively correlated and (2) the magnitude of acceleration at a specific time point and interval is correlated with its neighboring points. We defined a statistic value M as a function of time and the magnitude of maximal acceleration. We labeled and processed collected data and determined the relationship between M value, compression rate and CCD. We built a model accordingly, and developed a smartwatch app capable of detecting CCD. For validation, researchers wore a smartwatch with the preinstalled app and performed chest compression-only CPR on the manikin at target sessions. We compared the CCD results given by the smartwatch and the reference using the Wilcoxon Signed Rank Test (WSRT), and used Bland-Altman (BA) analysis to assess the agreement between the two methods.ResultsWe analyzed a total of 3978 compressions that covered the target rate of 80-140/min and CCD of 4-7 cm. WSRT showed that there was no significant difference between the two methods (P = 0.084). By BA analysis the mean of differences was 0.003 and the bias between the two methods was not significant (95% CI: -0.079 to 0.085).ConclusionOur study indicates that the algorithm developed for estimating CCD based on a smartwatch with a built-in accelerometer is promising. Further studies will be conducted to evaluate its application for CPR training and clinical practice.Copyright © 2018. Published by Elsevier Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…