• Conf Proc IEEE Eng Med Biol Soc · Jan 2011

    Long-term performance of a CE-approved telemetric intracranial pressure monitoring.

    • Michael Kiefer, Sebastian Antes, Melanie Schmitt, Inga Krause, and Regina Eymann.
    • Department of Neurosurgery, Saarland University, Medical School, Homburg-Saar 66421,Germany. Michael.Kiefer@uks.eu
    • Conf Proc IEEE Eng Med Biol Soc. 2011 Jan 1; 2011: 2246-9.

    AbstractTelemetric intracranial pressure (ICP) monitoring has been a challenge throughout several decades. Major obstruction was to minimize zero drift of absolute pressure sensors. A new promising product demonstrating in-vitro excellent long-term stability has been tested for its reliability in an animal model with a follow-up of up to 2 years. In "minipigs" sub-dural (Raumedic-STel®, Helmbrechts Germany) and intraparenchymal (Raumedic-PTel®) telemetric ICP probes have been inserted. Standard ICP probes (Raumedic Neurovent P®) served as controls. In regular intervals of 3 months the telemetrically and conventionally measured ICP have been compared. For each control a new conventional ICP probe has been inserted frontally to the telemetric device in the generalized anesthetized minipigs, resulting in overall 38 comparisons. Bland-Altman-plots, Chi2-tests and matched pair T-tests (significance level < 0.05) were used for data-analysis. The zero-shift was -1.7 ± 7.6 mm Hg (limits of agreement: 4.4 ± 1.9 mm Hg) and -3.0 ± 6.0 mm Hg (limits of agreement: 3.6 ± 2.6 mm Hg) in STel and PTel respectively meeting well the devices specification of ± 2 mm Hg drift per year. The reliability of both telemetric probes has been proved as quite comparable (p=0.2). These new telemetric ICP probes demonstrate reliable data during at least the first 6 months after implantation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…