• Childs Nerv Syst · Apr 2014

    Feasibility of telemetric ICP-guided valve adjustments for complex shunt therapy.

    • Florian Baptist Freimann, Matthias Schulz, Hannes Haberl, and Ulrich-Wilhelm Thomale.
    • Department of Neurosurgery, Charité - Universitätsmedizin Berlin, Berlin, Germany.
    • Childs Nerv Syst. 2014 Apr 1; 30 (4): 689-97.

    ObjectThe advances in shunt valve technology towards modern adjustable differential pressure (DP) valves and adjustable gravitational assisted valves result in an increasing complexity of therapeutical options. Modern telemetric intracranial pressure (ICP) sensors may be helpful in their application for diagnostic purposes in shunt therapy. We present our first experiences on telemetric ICP-guided valve adjustments in cases with the combination of an adjustable DP valve and adjustable gravitational unit.MethodsFour consecutive cases were evaluated in a retrospective review who had received a proGAV adjustable, gravitational assisted DP valve with secondary in-line implantation of an adjustable shunt assistant (proSA), together with a telemetric ICP sensor (Neurovent-P-tel) between December 2010 and June 2012 in our institution. The measured ICP values and the corresponding valve adjustments were analyzed in correlation with the clinical course and the cranial imaging of the patients.ResultsNo surgery-related complications were observed after implantation of the proSA and the telemetric ICP sensor additional to the proGAV. ICP values could actively be influenced by adjustments of the respective valve units. An increase of the position depending resistance of the proSA resulted in significant attenuated negative ICP values for the standing position, while adjustments of the proGAV could be detected not only in a supine position but also in a standing position. A clinical improvement could be achieved in all cases.ConclusionThe combination of adjustability in the differential pressure valve and the gravitational unit reveals a complex combination which may be difficult to adapt only according to clinical information. Telemetric ICP-guided valve adjustments seem to be a promising tool as an objective measure according to different body positions. Further investigations are needed to select the patients for these costly implants.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.