• J Vasc Access · Sep 2019

    Randomized Controlled Trial Multicenter Study

    Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China.

    • Yu-Xia Yin, Wei Gao, Xu-Ying Li, Wei Lu, Qian-Hong Deng, Cui-Yun Zhao, Xue-Rong Liu, Chao Zhou, Wen-Bo Hou, Shou-Tao Lu, Guang Liu, Lu-Ning Wang, Mao-Quan Li, and Hai-Jun Zhang.
    • 1 School of Materials Science and Engineering, University of Science & Technology Beijing, Beijing, China.
    • J Vasc Access. 2019 Sep 1; 20 (5): 524-529.

    IntroductionUltrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device.MethodsOur study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip.ResultsNo insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%-93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%-81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%-99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%-89.2%) observed in the anatomical landmark group (p < 0.001).ConclusionThese results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…