Comparative Study Observational Study
Epidural electrical stimulation test versus local anesthetic test dose for thoracic epidural catheter placement: a prospective observational study.
- Mrinalini Balki, Archana Malavade, Xiang Y Ye, and Umamaheswary Tharmaratnam.
- Department of Anesthesia and Pain Management, Mount Sinai Hospital, University of Toronto, 600 University Avenue, Toronto, ON, M5G 1X5, Canada. Mrinalini.balki@uhn.ca.
- Can J Anaesth. 2019 Apr 1; 66 (4): 380-387.
PurposeThis study examined the concordance between epidural electrical stimulation test (EEST) and local anesthetic (LA) test dose to indicate correct thoracic epidural catheter position. The relationship between the test results and epidural postoperative analgesia was also assessed.MethodsThis prospective observational cohort study was done in patients receiving thoracic epidural analgesia for abdominal surgery. After insertion, the epidural catheter was tested using a nerve stimulator to elicit a motor response. The LA test dose was then administered, and sensory block to ice and pinprick was assessed. The primary outcome was the presence/absence of motor response to EEST and sensory block to test dose. Concordance of responses was assessed using kappa statistics, and their predictive power of postoperative epidural analgesia was evaluated.ResultsSixty-eight thoracic epidural catheters were inserted, of which 62 were used perioperatively. The kappa agreement between EEST and LA test dose responses was moderate at 0.42 (95% confidence interval [CI], 0.18 to 0.67). Positive responses to EEST and LA test dose were observed in 62 (100%) and 50 (81%) patients, respectively, while 52 patients (84%) showed adequate analgesia postoperatively. The sensitivity (95% CI) of EEST and LA test dose to predict adequate postoperative epidural analgesia was 1 (0.93 to 1) and 0.79 (0.65 to 0.89), respectively, and the positive predictive values (95% CI) of EEST and LA test dose were 0.84 (0.75 to 0.93) and 0.82 (0.71 to 0.92), respectively.ConclusionFollowing thoracic epidural catheter insertion, the responses to the EEST and LA test dose showed "moderate" agreement. The EEST has a higher sensitivity than the LA test dose to predict adequate epidural analgesia following abdominal surgery, however, both tests have a comparable positive predictive value.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.